Suppr超能文献

骶髂关节炎症和骨转换的不对称性:通过氟代脱氧葡萄糖(FDG)和氟化钠(NaF)PET/CT进行评估

Sacroiliac Joint Asymmetry Regarding Inflammation and Bone Turnover: Assessment by FDG and NaF PET/CT.

作者信息

Al-Zaghal Abdullah, Yellanki Dani P, Kothekar Esha, Werner Thomas J, Høilund-Carlsen Poul F, Alavi Abass

机构信息

Department of Radiology, Hospital of the University of Pennsylvania, PA, USA.

Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark.

出版信息

Asia Ocean J Nucl Med Biol. 2019 Spring;7(2):108-114. doi: 10.22038/AOJNMB.2019.40820.1275.

Abstract

OBJECTIVES

This study was undertaken to determine the role of computed tomography (CT)-based methodology to segment the SI joint and quantify the metabolic activity using positron emission tomography (PET). We measured tracer uptake in the right and left SI joints independently to look for differences between the two sides. Further, we correlated tracer uptake with BMI and studied the inter-observer variation with regard to estimated tracer uptake in the SI joints.

METHODS

In this retrospective study, a total of 103 subjects (48 females, 55 males) from the CAMONA study database collected 2012-2016 at Odense University Hospital in Denmark were included. Mean age was 48±14.59 years, mean BMI was 26.68±4.31 kg/m. The SI joints were segmented on fused PET/CT images using a 3D growing algorithm with adjustable upper and lower Hounsfield Units (HU) thresholds. The metabolic activities on the two sides were correlated with BMI.

RESULTS

For FDG, we found a higher average SUV on the right side (right: 1.3±0.33, left: 1.13±0.30; <0.0001). Similarly, for NaF, the uptake was higher on the right side (right: 5.9±1.29, left: 4.27±1.23; <0.0001). Positive correlations were present between BMI and FDG uptake (P<0.01) as well as NaF uptake (P<0.01).

CONCLUSION

The PET-based molecular imaging probes along with the CT-based segmentation techniques revealed a significant difference in the metabolic activity between the two SI joints with higher inflammation and reactive bone formation on the right side. FDG and NaF uptakes correlated significantly and positively with BMI.

摘要

目的

本研究旨在确定基于计算机断层扫描(CT)的方法在骶髂关节分割以及使用正电子发射断层扫描(PET)定量代谢活性方面的作用。我们分别测量左右骶髂关节的示踪剂摄取情况,以寻找两侧之间的差异。此外,我们将示踪剂摄取与体重指数(BMI)相关联,并研究观察者间在骶髂关节示踪剂摄取估计方面的差异。

方法

在这项回顾性研究中,纳入了丹麦欧登塞大学医院2012年至2016年收集的CAMONA研究数据库中的103名受试者(48名女性,55名男性)。平均年龄为48±14.59岁,平均BMI为26.68±4.31kg/m²。使用具有可调节的上、下亨氏单位(HU)阈值的三维生长算法在融合的PET/CT图像上分割骶髂关节。两侧的代谢活性与BMI相关联。

结果

对于氟代脱氧葡萄糖(FDG),我们发现右侧的平均标准化摄取值(SUV)更高(右侧:1.3±0.33,左侧:1.13±0.30;P<0.0001)。同样,对于氟化钠(NaF),右侧的摄取更高(右侧:5.9±1.29,左侧:4.27±1.23;P<0.0001)。BMI与FDG摄取(P<0.01)以及NaF摄取(P<0.01)之间存在正相关。

结论

基于PET的分子成像探针与基于CT的分割技术显示,两个骶髂关节之间的代谢活性存在显著差异,右侧具有更高的炎症和反应性骨形成。FDG和NaF摄取与BMI显著正相关。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3b4a/6661309/2e4a88255439/AOJNMB-7-108-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验