Suppr超能文献

不同重新参考方法对自发产生的耳部脑电图的影响。

Effects of Different Re-referencing Methods on Spontaneously Generated Ear-EEG.

作者信息

Choi Soo-In, Hwang Han-Jeong

机构信息

Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi, South Korea.

出版信息

Front Neurosci. 2019 Aug 7;13:822. doi: 10.3389/fnins.2019.00822. eCollection 2019.

Abstract

In recent years, electroencephalography (EEG) measured around the ears, called ear-EEG, has been introduced to develop unobtrusive and ambulatory EEG-based applications. When measuring ear-EEGs, the availability of a reference site is restricted due to the miniaturized device structure, and therefore a reference electrode is generally placed near the recording electrodes. As the electrical brain activity recorded at a reference electrode closely placed to recording electrodes may significantly cancel or influence the brain activity recorded by the recording electrodes, an appropriate re-referencing method is often required to mitigate the impact of the reference brain activity. In this study, therefore, we systematically investigated the impact of different re-referencing methods on ear-EEGs spontaneously generated from endogenous paradigms. To this end, we used two ear-EEG datasets recorded behind both ears while subjects performed an alpha modulation task [eyes-closed (EC) and eyes-open (EO)] and two mental tasks [mental arithmetic (MA) and mental singing (MS)]. The measured ear-EEGs were independently re-referenced using five different methods: (i) all-mean, (ii) contralateral-mean, (iii) ipsilateral-mean, (iv) contralateral-bipolar, and (v) ipsilateral-bipolar. We investigated the changes in alpha power during EO and EC tasks, as well as event-related (de) synchronization (ERD/ERS) during MA and MS. To evaluate the effects of re-referencing methods on ear-EEGs, we estimated the signal-to-noise ratios (SNRs) of the two ear-EEG datasets, and assessed the classification performance of the two mental tasks (MA vs. MS). Overall patterns of changes in alpha power and ERD/ERS were similar among the five re-referencing methods, but the contralateral-mean method showed statistically higher SNRs than did the other methods for both ear-EEG datasets, except in the contralateral-bipolar method for the two mental tasks. In concordance with the SNR results, classification performance was also statistically higher for the contralateral-mean method than it was for the other re-referencing methods. The results suggest that employing contralateral mean information can be an efficient way to re-reference spontaneously generated ear-EEGs, thereby maximizing the reliability of ear-EEG-based applications in endogenous paradigms.

摘要

近年来,在耳朵周围测量的脑电图(EEG),即耳脑电图,已被引入以开发基于脑电图的非侵入性和动态应用。在测量耳脑电图时,由于设备结构小型化,参考位点的可用性受到限制,因此参考电极通常放置在记录电极附近。由于放置在靠近记录电极的参考电极处记录的脑电活动可能会显著抵消或影响记录电极记录的脑电活动,因此通常需要一种合适的重新参考方法来减轻参考脑电活动的影响。因此,在本研究中,我们系统地研究了不同重新参考方法对由内源性范式自发产生的耳脑电图的影响。为此,我们使用了两个耳脑电图数据集,这些数据集是在受试者执行α调制任务[闭眼(EC)和睁眼(EO)]以及两个心理任务[心算(MA)和心理歌唱(MS)]时在双耳后方记录的。使用五种不同方法对测量的耳脑电图进行独立重新参考:(i)全均值,(ii)对侧均值,(iii)同侧均值,(iv)对侧双极,和(v)同侧双极。我们研究了睁眼和闭眼任务期间α功率的变化,以及心算和心理歌唱期间的事件相关(去)同步(ERD/ERS)。为了评估重新参考方法对耳脑电图的影响,我们估计了两个耳脑电图数据集的信噪比(SNR),并评估了两个心理任务(心算与心理歌唱)的分类性能。在五种重新参考方法中,α功率和ERD/ERS的总体变化模式相似,但对侧均值方法在两个耳脑电图数据集上的信噪比在统计学上高于其他方法,但在两个心理任务的对侧双极方法中除外。与信噪比结果一致,对侧均值方法的分类性能在统计学上也高于其他重新参考方法。结果表明,采用对侧均值信息可能是重新参考自发产生的耳脑电图的有效方法,从而最大限度地提高基于耳脑电图的应用在内源性范式中的可靠性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/164c/6692921/c5b3c5511764/fnins-13-00822-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验