Suppr超能文献

使用简单自动验光仪对有晶状体眼和人工晶状体眼的色差进行临床评估。

Clinical assessment of chromatic aberration in phakic and pseudophakic eyes using a simple autorefractor.

作者信息

Millán María S, Vega Fidel, Poyales Francisco, Garzón Nuria

机构信息

Departament d'Òptica i Optometria, Universitat Politècnica de Catalunya, BARCELONATECH. ViolinistaVellsolà 37, 08222 Terrassa, Spain.

IOA Madrid, Innova Ocular. Galileo 104, 28003 Madrid, Spain.

出版信息

Biomed Opt Express. 2019 Jul 22;10(8):4168-4178. doi: 10.1364/BOE.10.004168. eCollection 2019 Aug 1.

Abstract

We describe a psychophysical method and a simple setup - an autorefractor with a Scheiner disc, sequentially illuminated with red and blue lights - for the clinical assessment of the longitudinal chromatic aberration (LCA) in phakic and pseudophakic patients. This method applies to the unaccommodated eye, even in the presence of positive or negative refractive errors and astigmatism. It measures the chromatic difference of refraction as an estimate of LCA. We built a proof of concept from inexpensive and off-the-shelf optomechanical components with which we obtained the preliminary clinical results presented in the paper. We considered one control group of phakic patients and three groups of pseudophakic patients with monofocal implants of different designs and materials. The results, satisfactory and consistent with those reported by other researchers in related works, demonstrate the method and system feasibility.

摘要

我们描述了一种心理物理学方法和一种简单的装置——带有施奈德盘的自动验光仪,用红色和蓝色光依次照明——用于临床评估有晶状体眼和人工晶状体眼患者的纵向色差(LCA)。该方法适用于未调节的眼睛,即使存在正或负屈光不正和散光。它测量折射的色差作为LCA的估计值。我们用廉价的现成光学机械部件构建了一个概念验证,并由此获得了本文中呈现的初步临床结果。我们考虑了一组有晶状体眼患者作为对照组,以及三组植入不同设计和材料的单焦点人工晶状体的人工晶状体眼患者。结果令人满意,且与其他研究人员在相关工作中报告的结果一致,证明了该方法和系统的可行性。

相似文献

2
In vivo longitudinal chromatic aberration of pseudophakic eyes.人工晶状体眼的体内纵向色差
Optom Vis Sci. 2014 Feb;91(2):240-6. doi: 10.1097/OPX.0000000000000137.
7
The effect of chromatic dispersion on pseudophakic optical performance.色散对人工晶状体光学性能的影响。
Br J Ophthalmol. 2007 Sep;91(9):1225-9. doi: 10.1136/bjo.2007.118745. Epub 2007 May 2.

本文引用的文献

3
Extended depth of focus intraocular lens: Chromatic performance.扩展焦深人工晶状体:色差性能。
Biomed Opt Express. 2017 Aug 31;8(9):4294-4309. doi: 10.1364/BOE.8.004294. eCollection 2017 Sep 1.
9
In vivo longitudinal chromatic aberration of pseudophakic eyes.人工晶状体眼的体内纵向色差
Optom Vis Sci. 2014 Feb;91(2):240-6. doi: 10.1097/OPX.0000000000000137.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验