Laboratorio de Óptica, Instituto Universitario de investigación en Óptica y Nanofísica (IUiOyN), Universidad de Murcia, Campus de Espinardo (Ed. 34), 30100 Murcia, Spain.
Invest Ophthalmol Vis Sci. 2013 May 1;54(5):3594-9. doi: 10.1167/iovs.13-11956.
The natural lens may provide some compensatory optical effect in the periphery. When it is substituted by an IOL during cataract surgery, the quality of the peripheral optics will be modified. We compared the peripheral image quality in the eyes of patients with one eye implanted with a monofocal IOL and the fellow eye still with the natural precataract lens.
We used a scanning peripheral Hartmann-Shack wavefront sensor to measure the central 80° of visual angle along the horizontal meridian. Twelve patients with ages ranging between 65 to 81 years were evaluated. The results of the phakic and pseudophakic eyes were compared using the spherical equivalent, astigmatism, higher order aberrations, and the Strehl ratio. The statistical differences at each angle between the two eyes were evaluated.
In the eyes implanted with IOLs, the peripheral mean spherical equivalent was slightly more myopic than in the phakic eyes, although the differences were only significant for some angles. Astigmatism increased much faster in the periphery for the pseudophakic eyes as compared with the phakic eyes. The mean values were significantly different from 9° and 17° outwards at the temporal and nasal retina, respectively. As an example, at 30°, eyes implanted with IOLs presented 1.5 diopters (D) of additional astigmatism. The higher order aberrations were not significantly different between the two groups.
Eyes implanted with monofocal IOLs present more astigmatism in the periphery than the healthy older eyes. This suggests that the crystalline lens provides a beneficial effect to partially compensate off-axis astigmatism. The degradation of the peripheral retinal image may reduce the pseudophakic patient's performance in common visual tasks.
自然晶状体可能在外周提供一些补偿光学效果。当白内障手术中用人工晶状体替代它时,周边光学质量将发生改变。我们比较了单焦点人工晶状体植入术后一眼和未手术眼(即仍保留白内障前晶状体)的周边图像质量。
我们使用扫描周边哈特曼-夏克波前传感器测量水平子午线的中央 80°视角。评估了 12 名年龄在 65 至 81 岁之间的患者。使用等效球镜、散光、高阶像差和斯特列尔比比较了未手术眼和已手术眼的结果。评估了两眼在每个角度的差异。
在植入人工晶状体的眼中,周边平均等效球镜稍近视,尽管仅在某些角度的差异有统计学意义。与未手术眼相比,人工晶状体眼的周边散光增加更快。在颞侧和鼻侧视网膜,从 9°和 17°开始,平均值差异有统计学意义。例如,在 30°处,植入人工晶状体的眼中有 1.5 屈光度的额外散光。两组之间高阶像差无显著差异。
植入单焦点人工晶状体的眼中,周边散光比健康的老年眼中更多。这表明晶状体提供了有益的效果,部分补偿了离轴散光。周边视网膜图像质量的下降可能会降低人工晶状体患者在常见视觉任务中的表现。