Department of Ophthalmology, Medical University Innsbruck, Innsbruck, Austria.
Department of Medical Statistics, Informatics, and Health Economics, Medical University Innsbruck, Innsbruck, Austria.
Eur J Ophthalmol. 2020 Nov;30(6):1397-1402. doi: 10.1177/1120672119873210. Epub 2019 Aug 30.
To evaluate the imaging characteristics of choroidal melanoma before and after proton beam radiotherapy via Optos ultra-wide-field scanning laser ophthalmoscopy.
Retrospective, descriptive study of choroidal melanoma patients treated with proton beam radiotherapy. All patients underwent full clinical evaluation, including best-corrected visual acuity, ultrasound examination and ultra-wide-field scanning laser ophthalmoscopy imaging in the pseudo-colour (red and green channel) as well as auto-fluorescence mode. Tumours were classified and evaluated according to their location, size, presence of subretinal fluid, drusen, orange pigment and reflectance intensity in ultra-wide-field scanning laser ophthalmoscopy. Tumour sonographic (basal diameter, height) and ultra-wide-field scanning laser ophthalmoscopy imaging dimensions (maximal diameter) were documented.
A total of 39 eyes (38 patients) were followed for 24 months (range 6-48 months). Mean best-corrected visual acuity dropped from 20/40 to 20/63 after proton beam radiotherapy. There was no change in the imaging tumour characteristics during follow-up. Subretinal fluid changes were better detected in the autofluorescence compared to pseudo-colour mode. Mean tumour diameter did not significantly change in the ultra-wide-field scanning laser ophthalmoscopy although it did so in the ultrasound. No patient showed local tumour recurrence.
The ultra-wide-field scanning laser ophthalmoscopy imaging characteristics of choroidal melanoma in the Optos system do not significantly change after proton beam radiotherapy after a mean follow-up of 2 years.
通过 Optos 超广角扫描激光检眼镜评价质子束放疗前后脉络膜黑色素瘤的影像学特征。
对接受质子束放疗的脉络膜黑色素瘤患者进行回顾性、描述性研究。所有患者均接受了全面的临床评估,包括最佳矫正视力、超声检查和超广角扫描激光检眼镜的假彩色(红、绿通道)和自发荧光模式成像。根据肿瘤的位置、大小、是否存在视网膜下积液、渗出物、橙色色素和超广角扫描激光检眼镜的反射强度对肿瘤进行分类和评估。记录肿瘤的超声(基底直径、高度)和超广角扫描激光检眼镜成像的尺寸(最大直径)。
共 39 只眼(38 例)接受了 24 个月(6-48 个月)的随访。平均最佳矫正视力从质子束放疗后的 20/40 下降到 20/63。在随访过程中,肿瘤的影像学特征没有变化。与假彩色模式相比,自发荧光模式更能更好地检测到视网膜下积液的变化。虽然在超声上肿瘤直径有显著变化,但在超广角扫描激光检眼镜上没有显著变化。没有患者出现局部肿瘤复发。
在平均随访 2 年后,Optos 系统的超广角扫描激光检眼镜成像特征在质子束放疗后脉络膜黑色素瘤没有明显变化。