Suppr超能文献

体外实验性白内障手术中冲洗/抽吸后残余眼科黏弹剂的定量。

Quantification of residual ophthalmic viscosurgical device after irrigation/aspiration in experimental cataract surgery in vitro.

机构信息

Department of Ophthalmology, Kashiwa Hospital, The Jikei University School of Medicine, Japan.

Department of Ophthalmology, Kashiwa Hospital, The Jikei University School of Medicine, Japan.

出版信息

J Cataract Refract Surg. 2019 Sep;45(9):1324-1329. doi: 10.1016/j.jcrs.2019.03.025.

Abstract

PURPOSE

To determine the distribution and quantity of ophthalmic viscosurgical device (OVD) retained in the lens capsular bag after irrigation/aspiration (I/A) in experimental cataract surgery.

SETTING

Department of Ophthalmology, Kashiwa Hospital, Jikei University School of Medicine, Japan.

DESIGN

Experimental study.

METHODS

Fifteen freshly enucleated porcine eyes were used. Sodium hyaluronate 1.0% (Healon) was mixed with a fixed concentration of silica nanoparticles encapsulating fluorescein isothiocyanate (labeled OVD), and it was injected separately into the capsular bag and injector cartridge for intraocular lens (IOL) insertion. After a 3-piece IOL (YA-60BBR) or a 1-piece IOL (iSert 255) was implanted within the capsular bag, OVD was removed by thorough I/A. Eyes that were injected with the labeled OVD into the capsular bag without IOL insertion were used as controls. The distribution of residual OVD in the capsular bag was observed under ultraviolet irradiation using Miyake-Apple view. Then, the excised capsular bag was dissolved in hydrogen fluoride, and silica concentration was measured quantitatively by elemental analysis.

RESULTS

The quantity of residual OVD in the capsular bag was 243.1 μg ± 1.3 (SD) in the 3-piece IOL-implanted group, 383.8 ± 11.1 μg in the 1-piece IOL-implanted group, and 99.0 ± 1.3 μg in the control group. In the 1-piece IOL-implanted eyes, OVD in the form of clumps tended to remain near the center of the optic on the posterior side, and the quantity of residual OVD was significantly greater than in 3-piece IOL-implanted eyes (P < .05).

CONCLUSION

The quantity of residual OVD after I/A could be determined indirectly using labeled OVD, and the quantity was significantly greater in 1-piece IOL-implanted eyes than in 3-piece IOL-implanted eyes.

摘要

目的

在实验性白内障手术中,通过冲洗/抽吸(I / A)确定在晶状体囊袋中的眼科粘弹剂(OVD)的分布和数量。

设置

日本顺天堂大学医学院柏原医院眼科。

设计

实验研究。

方法

使用 15 只新鲜摘出的猪眼。将透明质酸钠 1.0%(Healon)与固定浓度的包裹荧光素异硫氰酸酯的硅纳米粒子混合,并分别注入晶状体囊袋和注油器中以插入人工晶状体(IOL)。在 3 件式 IOL(YA-60BBR)或 1 件式 IOL(iSert 255)植入囊袋内后,通过彻底的 I / A 去除 OVD。将未插入 IOL 的标记 OVD注入囊袋的眼睛作为对照。使用 Miyake-Apple 视图在紫外线照射下观察囊袋中残留 OVD 的分布。然后,将切除的囊袋溶解在氢氟酸中,并通过元素分析定量测量硅浓度。

结果

在 3 件式 IOL 植入组中,囊袋中残留 OVD 的量为 243.1 ± 1.3(SD)μg,在 1 件式 IOL 植入组中为 383.8 ± 11.1 μg,在对照组中为 99.0 ± 1.3 μg。在 1 件式 IOL 植入的眼中,OVD 呈团块状,倾向于留在后侧的光学中心附近,残留 OVD 的量明显大于 3 件式 IOL 植入的眼(P <.05)。

结论

可以使用标记的 OVD 间接确定 I / A 后残留的 OVD 的量,并且在 1 件式 IOL 植入的眼中比在 3 件式 IOL 植入的眼中明显更多。