Suppr超能文献

A project of advanced solid-state neutron polarizer for PF1B instrument at Institut Laue-Langevin.

作者信息

Petukhov A K, Nesvizhevsky V V, Bigault T, Courtois P, Jullien D, Soldner T

机构信息

Institut Max von Laue-Paul Langevin, 71 avenue des Martyrs, Grenoble F-38042, France.

出版信息

Rev Sci Instrum. 2019 Aug;90(8):085112. doi: 10.1063/1.5114796.

Abstract

Among polarizers based on the neutron reflection from Super-Mirrors (SMs), solid-state neutron-optical devices have many advantages. The most relevant is the 5-10 times smaller size along the neutron beam direction compared to more traditional air-gap devices. An important condition for a good SM polarizer is the matching of the substrate SLD (Scattering Length Density) with the SM coating SLD for the spin-down component. For traditional Fe/Si SM on the Si substrate, this SLD step is positive when a neutron goes from the substrate to the SM, which leads to a significant degradation of the polarizer performance in the small Q region. This can be solved by replacing single-crystal Si substrates by single-crystal sapphire or quartz substrates. The latter shows a negative SLD step for the spin-down neutron polarization component at the interface with Fe and, therefore, avoid the total reflection regime in the small Q region. In order to optimize the polarizer performance, we formulate the concept of sapphire V-bender. We perform ray-tracing simulations of sapphire V-bender, compare results with those for traditional C-bender on Si, and study experimentally V-bender prototypes with different substrates. Our results show that the choice of substrate material, polarizer geometry, as well the strength and quality of magnetizing field have dramatic effect on the polarizer performance. In particular, we compare the performance of polarizer for the applied magnetic field strength of 50 mT and 300 mT. Only the large field strength (300 mT) provides an excellent agreement between the simulated and measured polarization values. For the double-reflection configuration, a record polarization >0.999 was obtained in the neutron wavelength band of 0.3-1.2 nm with only 1% decrease at 2 nm. Without any collimation, the polarization averaged over the full outgoing capture spectrum, 0.997, was found to be equal to the value obtained previously using only a double polarizer in the "crossed" (X-SM) geometry. These results are applied in a full-scale polarizer for the PF1B instrument.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验