Suppr超能文献

眼球旋转和隐形眼镜偏心对水平周边屈光度的影响。

Effects of eye rotation and contact lens decentration on horizontal peripheral refraction.

机构信息

Institute of Health & Biomedical Innovation and School of Optometry and Vision Science, Queensland University of Technology, Brisbane, Australia.

Institute for Ophthalmic Research, Eberhard Karls University Tuebingen, Tuebingen, Germany.

出版信息

Ophthalmic Physiol Opt. 2019 Sep;39(5):370-377. doi: 10.1111/opo.12641. Epub 2019 Sep 3.

Abstract

PURPOSE

Peripheral refraction is important in design of myopia control therapies. The aim was to investigate the influence of contact lens decentration associated with eye rotation on peripheral refraction in the horizontal visual field.

METHODS

Participants were 10 emmetropes and 10 myopes in good general and ocular health. Right eyes underwent cycloplegic peripheral refraction, using a Grand-Seiko WAM-5500 Autorefractor, in 5° steps to ±35° eccentricities along the horizontal visual field. Targets were fixated using eye rotation only or head rotation only. Refractions were measured without correction and with three types of contact lenses: single vision, a multifocal centre-distance aspheric with +2.50 D add and NaturalVue aspheric. Photographs of eyes during lens wear were taken for each eye rotation. Effects of visual field angle, lens type and test method (head or eye rotation) on vector components of relative peripheral refraction were evaluated using repeated measures anovas. Test method for each visual field angle/lens combination were compared via paired t-tests.

RESULTS

Horizontal decentration ranges across the visual field were 1.2 ± 0.6 mm for single vision and 1.2 ± 0.4 mm for multifocal lenses but smaller at 0.7 ± 0.4 mm for NaturalVue lenses. There were only two significant effects of test method across the visual field angle/lens type combinations (single vision: for emmetropes horizontal/vertical astigmatism component at 35° nasal with mean difference -0.38 D and for myopes spherical equivalent refraction at 20° temporal with mean difference +0.24 D).

CONCLUSION

Upon eye rotation the contact lenses decentred on the eye, but not enough to affect peripheral refraction. For the types assessed and for the horizontal visual field out to ±35° when measurements were performed with the Grand-Seiko WAM-5500 autorefractor, it is valid to use eye rotations to investigate peripheral refraction.

摘要

目的

周边屈光是近视控制疗法设计中的重要因素。本研究旨在探讨眼球旋转伴接触镜偏心对水平视野周边屈光度的影响。

方法

10 名正视者和 10 名近视患者参与本研究,他们的一般和眼部健康状况良好。右眼接受睫状肌麻痹周边屈光度检查,使用 Grand-Seiko WAM-5500 自动验光仪,在水平视野的 5°步距内以±35°的偏心距进行检查。目标仅通过眼球旋转或头部旋转进行固定。在不矫正和三种类型的接触镜(单焦点、+2.50 D 附加的多焦点中距离离焦型和 NaturalVue 非球面型)下测量屈光度。为每只眼的旋转拍摄了戴镜时的眼部照片。使用重复测量方差分析评估视野角、镜片类型和测试方法(头部或眼球旋转)对相对周边屈光度矢量分量的影响。通过配对 t 检验比较每个视野角/镜片组合的测试方法。

结果

单焦点镜片的水平偏心范围在整个视野内为 1.2±0.6mm,多焦点镜片为 1.2±0.4mm,而 NaturalVue 镜片则小至 0.7±0.4mm。在整个视野角/镜片类型组合中,只有两种测试方法的影响具有统计学意义(单焦点:正视者在 35°鼻侧的水平/垂直散光分量,平均差异-0.38D;近视者在 20°颞侧的等效球镜屈光度,平均差异+0.24D)。

结论

眼球旋转时,接触镜在眼球上偏心,但不足以影响周边屈光度。在评估的类型和水平视野±35°范围内,当使用 Grand-Seiko WAM-5500 自动验光仪进行测量时,使用眼球旋转来研究周边屈光度是有效的。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验