Suppr超能文献

多中心儿科影像患者剂量调查及法国更新诊断参考水平建议。第 1 部分:计算机断层扫描。

Multicentre survey on patient dose in paediatric imaging and proposal for updated diagnostic reference levels for France. Part 1: computed tomography.

机构信息

Institut de radioprotection et de sûreté nucléaire, 31 avenue de la Division Leclerc, Fontenay-aux-Roses, France.

Department of Pediatric Imaging, Hôpital d'enfants Armand-Trousseau APHP, 26 avenue du Docteur Arnold-Netter, Paris, France.

出版信息

Eur Radiol. 2020 Feb;30(2):1156-1165. doi: 10.1007/s00330-019-06405-3. Epub 2019 Sep 5.

Abstract

OBJECTIVES

To report on a dose survey conducted by the French societies of radiology and paediatric imaging (SFR and SFIPP) and the French public service expert in nuclear and radiological risks (IRSN), and to suggest new diagnostic reference levels (DRLs) for paediatric CT.

METHODS

Dose reports concerning children aged 0-15 years and five CT procedures (brain, petrous bone, mediastinum, lung and abdomen-pelvis) performed in 2015-2016 were collected from 15 imaging departments on a voluntary basis. Volume CT dose index (CTDI) and dose-length product (DLP) were recorded for at least 10 patients per procedure, per centre and per age group. New DRLs were calculated as the 3rd quartiles of the distributions of the median values.

RESULTS

Results from 3253 CT examinations were obtained. The exposure levels observed were much lower than for the previous surveys (2007-2008 and 2010-2013) and among the lowest values currently published. A good homogeneity between facilities was also observed. New DRLs are proposed for each procedure and age group.

CONCLUSIONS

This new survey contributes to the continuing optimisation process in French paediatric CT practice. Its results have been recently used to update the national paediatric CT DRLs.

KEY POINTS

• New national diagnostic reference levels (DRLs) are proposed for several paediatric CT procedures. • The DRLs proposed for brain, chest and abdomen-pelvis procedures are among the lowest published worldwide.

摘要

目的

报告法国放射学和儿科影像学协会(SFR 和 SFIPP)以及法国核与放射风险公共服务专家(IRSN)进行的剂量调查,并为儿科 CT 提出新的诊断参考水平(DRL)。

方法

从 2015 年至 2016 年,15 个影像科自愿收集了针对 0-15 岁儿童进行的 5 种 CT 检查(脑部、岩骨、纵隔、肺部和腹部-骨盆)的剂量报告。每个中心和每个年龄组至少记录了 10 名患者的容积 CT 剂量指数(CTDI)和剂量长度乘积(DLP)。新的 DRL 计算为中位数分布的第 3 四分位数。

结果

获得了 3253 次 CT 检查的结果。观察到的暴露水平远低于前几次调查(2007-2008 年和 2010-2013 年),也是目前公布的最低值之一。各设施之间也表现出良好的一致性。为每个程序和年龄组提出了新的 DRL。

结论

这项新调查为法国儿科 CT 实践的持续优化过程做出了贡献。其结果最近已用于更新国家儿科 CT DRL。

关键点

• 为几种儿科 CT 程序提出了新的国家诊断参考水平(DRL)。• 为脑部、胸部和腹部-骨盆程序提出的 DRL 是全球公布的最低值之一。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验