Suppr超能文献

安全相关环境声音识别在人工耳蜗植入候选者和使用者中。

Safety-relevant environmental sound identification in cochlear implant candidates and users.

机构信息

Department of Otolaryngology and Communication Sciences, Medical College of Wisconsin, Milwaukee, Wisconsin.

Department of Otolaryngology-Head and Neck Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio.

出版信息

Laryngoscope. 2020 Jun;130(6):1547-1551. doi: 10.1002/lary.28285. Epub 2019 Sep 9.

Abstract

OBJECTIVES/HYPOTHESIS: To compare the identification of safety-relevant environmental sounds between experienced cochlear implant (CI) users and CI candidates.

STUDY DESIGN

Cross-sectional.

METHODS

A sample of 19 adult, postlingually deaf CI candidates (CI-Cs), 47 experienced CI users (CI-Es), and a control group of 37 age-matched normal-hearing adults were assessed using the Familiar Environmental Sounds Test-Identification (FEST-I). A subset of 11 sounds relevant for safety were selected for analysis in the current study.

RESULTS

Analysis of safety-relevant sound identification accuracy revealed no significant difference in safety-relevant environmental sound identification skills between CI-E and CI-C participants, with average scores of 68.1% and 67.9%, respectively. Both performed substantially lower than age-matched normal hearing adults (95.1%). A significant moderate negative correlation (-0.4) was found between safety-relevant sound accuracy and chronological age only in one group, the CI-E group (r = -0.4, P < .005).

CONCLUSIONS

These findings fail to demonstrate superior performance in safety-relevant environmental sound identification among CI-Es compared with CI-Cs. Although preliminary, these findings suggest that identification of safety-relevant sounds is a significant area of weakness for both CI-Es and CI-Cs, both of whom may benefit from rehabilitation.

LEVEL OF EVIDENCE

4 Laryngoscope, 130:1547-1551, 2020.

摘要

目的/假设:比较有经验的人工耳蜗(CI)使用者和 CI 候选者识别与安全相关的环境声音的能力。

研究设计

横断面研究。

方法

对 19 名成年后天性耳聋 CI 候选者(CI-Cs)、47 名有经验的 CI 使用者(CI-Es)和 37 名年龄匹配的正常听力成年人的样本使用熟悉环境声音测试-识别(FEST-I)进行评估。本研究选择了 11 个与安全相关的声音子集进行分析。

结果

分析安全相关声音识别的准确性显示,CI-E 和 CI-C 参与者在安全相关环境声音识别技能方面没有显著差异,平均得分分别为 68.1%和 67.9%。两者均显著低于年龄匹配的正常听力成年人(95.1%)。仅在一个组,即 CI-E 组中,发现安全相关声音准确性与年龄呈显著中度负相关(-0.4)(r = -0.4,P <.005)。

结论

这些发现未能证明 CI-E 与 CI-C 相比,在识别与安全相关的环境声音方面表现出优越的性能。尽管初步,但这些结果表明,识别与安全相关的声音是 CI-E 和 CI-C 的一个显著弱点领域,两者都可能受益于康复。

证据水平

4 级喉镜,130:1547-1551,2020。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验