We have used intraoperative monitoring and stimulation of facial nerve function routinely in 301 consecutive otologic and neurotologic cases. The device has been safe, simple to use, and practical. Facial contraction is detected by a strain-gauge sensor in the corner of the mouth and is signalled audibly to the surgeon. Electrical stimulation of the facial nerve can be delivered through a sterile probe, which produces a constant-current-square-wave impulse. The device has several advantages: it signals unintentional mechanical stimulation of the facial nerve during surgery; it allows mapping of the nerve through soft tissue, tumor, and bone; it predicts dehiscences in the bony covering of the nerve; and it allows confirmation of the electrical integrity of the nerve before and after surgery. In this paper we present a technical description of the device, relevant intraoperative electrical measurements, and illustrative case examples. Although the device does not replace anatomic knowledge and surgical ability, it provides a margin of security during ear surgery. This system for intraoperative facial monitoring is practical, and the authors encourage its routine use.

摘要

我们在连续301例耳科和神经耳科病例中常规使用了术中面神经功能监测和刺激。该设备安全、易于使用且实用。通过嘴角的应变片传感器检测面部收缩,并向外科医生发出可听信号。面神经的电刺激可通过无菌探头进行,该探头产生恒流方波脉冲。该设备有几个优点:它能在手术过程中提示对面神经的无意机械刺激;它能通过软组织、肿瘤和骨骼对神经进行定位;它能预测神经骨覆盖层的裂孔;它能在手术前后确认神经的电完整性。在本文中,我们介绍了该设备的技术描述、相关的术中电测量以及典型病例示例。虽然该设备不能替代解剖学知识和手术能力,但它在耳部手术中提供了一定的安全保障。这种术中面部监测系统很实用,作者鼓励常规使用。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验