Influence of In-Situ Electrochemical Oxidation on Implant Surface and Colonizing Microorganisms Evaluated by Scanning Electron Microscopy.

作者信息

Göltz Maximilian, Koch Maximilian, Detsch Rainer, Karl Matthias, Burkovski Andreas, Rosiwal Stefan

机构信息

Division of Ultra-Hard Coatings, Department of Material Sciences, University of Erlangen-Nuremberg, 91058 Erlangen, Germany.

Microbiology Division, Department of Biology, University of Erlangen-Nuremberg, 91058 Erlangen, Germany.

出版信息

Materials (Basel). 2019 Nov 30;12(23):3977. doi: 10.3390/ma12233977.

Abstract

Peri-implantitis is a worldwide increasing health problem, caused by infection of tissue and bone around an implant by biofilm-forming microorganisms. Effects of peri-implantitis treatment using mechanical debridement, air particle abrasion and electrochemical disinfection on implant surface integrity were compared. Dental implants covered with bacterial biofilm were cleaned using mechanical debridement and air particle abrasion. In addition, implants were disinfected using a novel electrochemical technique based on an array of boron-doped diamond (BDD) coated electrodes. Following treatment and preparation, the implants were inspected by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). Mechanical debridement led to changes in surface topography destroying the manufacturer's medium-rough surface by scratch formation. Air particle abrasion led to accumulation of the abrasive used on the implant surface. With both treatment options, appearance of bacteria and yeasts was not affected. In contrast, electrochemical disinfection did not cause alterations of the implant surface but resulted in distorted microbial cells. Electrochemical disinfection of implant surfaces using BDD electrodes may constitute a promising treatment option for cleaning dental implant surfaces without negatively affecting materials and surface properties.

摘要

种植体周围炎是一个在全球范围内日益严重的健康问题,它是由形成生物膜的微生物感染种植体周围的组织和骨所引起的。研究比较了采用机械清创、空气颗粒研磨和电化学消毒治疗种植体周围炎对种植体表面完整性的影响。对覆盖有细菌生物膜的牙科种植体进行机械清创和空气颗粒研磨清洁。此外,使用基于一系列硼掺杂金刚石(BDD)涂层电极的新型电化学技术对种植体进行消毒。处理和制备后,通过扫描电子显微镜(SEM)和能量色散X射线光谱仪(EDX)对种植体进行检查。机械清创导致表面形貌发生变化,通过划痕形成破坏了制造商的中等粗糙度表面。空气颗粒研磨导致磨料在种植体表面堆积。两种治疗方法均未影响细菌和酵母菌的出现。相比之下,电化学消毒不会导致种植体表面改变,但会使微生物细胞变形。使用BDD电极对种植体表面进行电化学消毒可能是一种有前景的治疗选择,可用于清洁牙科种植体表面,而不会对材料和表面性能产生负面影响。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3216/6926823/fcaac3e75d6a/materials-12-03977-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验