• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Pediatric defibrillation: importance of paddle size in determining transthoracic impedance.

作者信息

Atkins D L, Sirna S, Kieso R, Charbonnier F, Kerber R E

机构信息

Cardiovascular Center, University of Iowa, Iowa City.

出版信息

Pediatrics. 1988 Dec;82(6):914-8.

PMID:3186384
Abstract

Transthoracic impedance is a major determinant of successful defibrillation or cardioversion, but no data are available concerning the range and determinants of transthoracic impedance in children. Transthoracic impedance was measured in ten ambulatory infants, 6 weeks to 9 months of age, and 37 children, 1.5 to 15 years of age, using a previously validated "test pulse" technique that measures transthoracic impedance without actually delivering a shock. We used hand-held "pediatric" (21 cm2) and "adult" (83 cm2) electrode paddles coated with either Redux paste or Redux creme. Transthoracic impedance in children was 108 +/- 24 omega (range 61 to 212 omega) using pediatric paddles. Using adult paddles lowered the transthoracic resistance by 47% to 57 +/- 11 omega (range 29 to 101 omega), P less than .05. In infants, transthoracic impedance (measured only with pediatric paddles) was 94 +/- 17 omega (range 74 to 124 omega). Using Redux paste as the coupling agent reduced transthoracic impedance by 13% (P less than .05). Transthoracic impedance was significantly but poorly related to body weight and body surface areas, but the correlations were not sufficiently high to be clinically useful. These data indicate that the larger adult electrode paddles will minimize transthoracic impedance and should be used when the child's thorax is large enough to permit electrode to chest contact over the entire paddle surface. This transition occurred at an approximate weight of 10 kg.

摘要

相似文献

1
Pediatric defibrillation: importance of paddle size in determining transthoracic impedance.
Pediatrics. 1988 Dec;82(6):914-8.
2
Pediatric defibrillation: current flow is improved by using "adult" electrode paddles.小儿除颤:使用“成人”电极板可改善电流传导。
Pediatrics. 1994 Jul;94(1):90-3.
3
Transthoracic impedance study with large self-adhesive electrodes in two conventional positions for defibrillation.使用大型自粘电极在两个传统除颤位置进行经胸阻抗研究。
Physiol Meas. 2006 Oct;27(10):1009-22. doi: 10.1088/0967-3334/27/10/007. Epub 2006 Aug 25.
4
External defibrillation in the left lateral position--a comparison of manual paddles with self-adhesive pads.
Resuscitation. 2004 Dec;63(3):283-6. doi: 10.1016/j.resuscitation.2004.06.002.
5
Is optimal paddle force applied during paediatric external defibrillation?
Resuscitation. 2004 Jan;60(1):29-32. doi: 10.1016/j.resuscitation.2003.09.001.
6
What is the optimal paddle force during paediatric external defibrillation?
Resuscitation. 2003 Oct;59(1):83-8. doi: 10.1016/s0300-9572(03)00173-4.
7
A percutaneous catheter-based system for the measurement of potential gradients applicable to the study of transthoracic defibrillation.一种基于经皮导管的系统,用于测量适用于经胸除颤研究的电位梯度。
Pacing Clin Electrophysiol. 2007 Feb;30(2):166-74. doi: 10.1111/j.1540-8159.2007.00645.x.
8
Differential contribution of skin impedance and thoracic volume to transthoracic impedance during external defibrillation.体外除颤期间皮肤阻抗和胸廓容积对经胸阻抗的不同贡献。
Resuscitation. 2004 Feb;60(2):171-4. doi: 10.1016/j.resuscitation.2003.10.001.
9
Disposable defibrillator electrodes.一次性除颤器电极。
Heart Lung. 1977 Jan-Feb;6(1):127-30.
10
Low energy biphasic waveform cardioversion of atrial arrhythmias in pediatric patients and young adults.小儿患者和年轻成人房性心律失常的低能量双相波电复律
Pacing Clin Electrophysiol. 2006 Dec;29(12):1383-6. doi: 10.1111/j.1540-8159.2006.00551.x.

引用本文的文献

1
Pad size, orientation, and placement for defibrillation during basic life support: A systematic review.基础生命支持期间除颤的电极片尺寸、方向和放置:一项系统评价。
Resusc Plus. 2025 Jul 14;25:101030. doi: 10.1016/j.resplu.2025.101030. eCollection 2025 Sep.
2
A Systematic Review of the Transthoracic Impedance during Cardiac Defibrillation.经胸阻抗在心脏除颤中的系统评价
Sensors (Basel). 2022 Apr 6;22(7):2808. doi: 10.3390/s22072808.
3
Pediatric basic and advanced life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations.
儿科基础与高级生命支持:2010年国际心肺复苏与心血管急救科学及治疗建议共识。
Pediatrics. 2010 Nov;126(5):e1261-318. doi: 10.1542/peds.2010-2972A. Epub 2010 Oct 18.
4
Part 10: Pediatric basic and advanced life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations.第十部分:儿科基础和高级生命支持:2010 年国际心肺复苏和紧急心血管急救科学共识及治疗推荐。
Circulation. 2010 Oct 19;122(16 Suppl 2):S466-515. doi: 10.1161/CIRCULATIONAHA.110.971093.
5
Defibrillation in children.儿童除颤
J Emerg Trauma Shock. 2010 Jul;3(3):261-6. doi: 10.4103/0974-2700.66526.
6
Elevated impedance during cardioversion in neonates with atrial flutter.新生儿心房扑动在心脏复律期间阻抗升高。
Pediatr Cardiol. 2009 May;30(4):436-40. doi: 10.1007/s00246-009-9413-6. Epub 2009 Apr 14.
7
Guidelines for paediatric life support. Paediatric Life Support Working Party of the European Resuscitation Council.儿科生命支持指南。欧洲复苏委员会儿科生命支持工作组
BMJ. 1994 May 21;308(6940):1349-55.