评价一种带涂层刀片喷雾串联质谱检测法,作为一种新工具用于全血中免疫抑制药物的测定。

Evaluation of a coated blade spray-tandem mass spectrometry assay as a new tool for the determination of immunosuppressive drugs in whole blood.

机构信息

Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada.

Restek Corporation, Bellefonte, PA, 16823, USA.

出版信息

Anal Bioanal Chem. 2020 Aug;412(21):5067-5076. doi: 10.1007/s00216-019-02367-z. Epub 2020 Jan 6.

Abstract

Immunosuppressive drugs (ISDs) are primarily administered following solid organ transplant or for treatment of a variety of autoimmune conditions. Their principal function is to suppress the activity of the immune system; however, the levels must be carefully monitored due to adverse effects of over- or underadministration. A technology for rapid quantitative screening, named coated blade spray (CBS), was directly coupled to a triple quadrupole mass spectrometer (MS/MS) to measure the concentration of ISDs (i.e., cyclosporine A, tacrolimus, everolimus, sirolimus) in whole blood samples. We evaluated the stability of replicate measurements over a 10-day period (precision), assessed linearity and limit of quantification, and performed a method comparison against a validated clinical immunoassay (Abbott ARCHITECT). Total interday variation of less than 5% for all target compounds at three different concentrations was achieved. The sensitivity of the method was determined as 0.25, 1, 1, and 2.5 ng/mL for everolimus, sirolimus, tacrolimus, and cyclosporine A, respectively. The concentrations of three immunosuppressive drugs in 284 patient samples (i.e., ~ 95 samples of cyclosporine A, tacrolimus, or sirolimus) obtained using the CBS-MS/MS methodology were compared with concentrations previously quantified on an Abbott ARCHITECT immunoassay system. Our analysis demonstrated significant statistical similarities between both methods. The results demonstrate that CBS-MS/MS is a suitable alternative to conventional methodologies for monitoring of ISDs from whole blood in a clinical setting. Graphical abstract.

摘要

免疫抑制剂(ISD)主要在实体器官移植后或用于治疗各种自身免疫性疾病时使用。它们的主要功能是抑制免疫系统的活性;然而,由于给药过多或过少的不良反应,必须仔细监测其水平。一种名为涂层刀片喷雾(CBS)的快速定量筛选技术被直接与三重四极杆质谱仪(MS/MS)耦合,以测量全血样本中 ISD(即环孢素 A、他克莫司、依维莫司、西罗莫司)的浓度。我们评估了在 10 天内重复测量的稳定性(精密度),评估了线性和定量下限,并与经过验证的临床免疫测定法(雅培 ARCHITECT)进行了方法比较。在三个不同浓度下,所有目标化合物的总日内变异小于 5%。该方法的灵敏度分别为 0.25、1、1 和 2.5 ng/mL,用于依维莫司、西罗莫司、他克莫司和环孢素 A。使用 CBS-MS/MS 方法获得的 284 个患者样本(即约 95 个环孢素 A、他克莫司或西罗莫司样本)中三种免疫抑制剂的浓度与以前在雅培 ARCHITECT 免疫测定系统中定量的浓度进行了比较。我们的分析表明两种方法之间存在显著的统计学相似性。结果表明,CBS-MS/MS 是一种替代传统方法的合适方法,可用于临床环境中监测全血中的 ISD。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验