Graduate School of Health Sciences, Dokuz Eylul University, Izmir, Turkey.
School of Physical Therapy and Rehabilitation, Dokuz Eylul University, Izmir, Turkey.
Hip Int. 2021 Jan;31(1):43-49. doi: 10.1177/1120700019888614. Epub 2020 Jan 13.
Performance-based outcome measures are becoming increasingly important in health care. The 2-minute walk test (2MWT) and the Timed Up and Go test (TUG) are frequently used in clinical trials as performance-based tests in many diseases including osteoarthritis. The purposes of this study were: (1) to determine test-retest reliability of data for the 2MWT and the TUG; (2) to determine minimal detectable change (MDC) scores for the TUG and 2MWT in patients with total hip arthroplasty (THA).
37 patients, who had undergone primary THA, were included. Patients twice performed trials for the 2MWT and TUG on the same day. In addition to demographic data of patients, the Harris Hip Score, 2MWT and TUG scores were recorded.
The TUG and 2MWT showed excellent test-retest reliability. The Intraclass correlation coefficient ICC (2,1), Standard error of measurement (SEM) and minimal detectable chance at the 95% CI (MDC) for TUG were 0.96, 0.59 seconds and 1.62 seconds respectively. The ICC (2,1), SEM and MDC for 2MWT were 0.96, 6.37 m and 17.56 m respectively.
Clinicians and researchers can be confident that greater changes than 1.62 seconds for TUG and 17.56 m for the 2MWT over time represent a real clinical change in rehabilitation process in patients with THA. Both the 2MWT and TUG may assist in early identification of patients who may need additional rehabilitation to reduce the potential for poor outcomes after THA. Therefore, both of these tests can be used in a clinical setting with a small measurement error.
基于表现的结果测量在医疗保健中变得越来越重要。在许多疾病中,包括骨关节炎,2 分钟步行测试(2MWT)和计时起立行走测试(TUG)经常被用作临床试验中的基于表现的测试。本研究的目的是:(1)确定 2MWT 和 TUG 的测试-重测数据的可靠性;(2)确定全髋关节置换术(THA)患者 TUG 和 2MWT 的最小可检测变化(MDC)评分。
纳入 37 名接受初次 THA 的患者。患者在同一天两次进行 2MWT 和 TUG 试验。除了患者的人口统计学数据外,还记录了 Harris 髋关节评分、2MWT 和 TUG 评分。
TUG 和 2MWT 显示出极好的测试-重测可靠性。TUG 的组内相关系数 ICC(2,1)、测量误差(SEM)和 95%CI 下的最小可检测机会(MDC)分别为 0.96、0.59 秒和 1.62 秒。2MWT 的 ICC(2,1)、SEM 和 MDC 分别为 0.96、6.37 米和 17.56 米。
临床医生和研究人员可以确信,TUG 超过 1.62 秒和 2MWT 超过 17.56 米的变化代表了 THA 康复过程中的真实临床变化。2MWT 和 TUG 都可以帮助早期识别可能需要额外康复以降低 THA 后不良结果风险的患者。因此,这两种测试都可以在具有较小测量误差的临床环境中使用。