Department of Radiology, Addenbrooke's Hospital and University of Cambridge, Cambridge, UK.
CamPARI Prostate Cancer Group, Addenbrooke's Hospital and University of Cambridge, Cambridge, UK.
Br J Radiol. 2020 Apr;93(1108):20190929. doi: 10.1259/bjr.20190929. Epub 2020 Feb 3.
To introduce capped biparametric (bp) MRI slots for follow-up imaging of prostate cancer patients enrolled in active surveillance (AS) and evaluate the effect on weekly variation in the number of AS cases and total MRI workload.
Three 20 min bpMRI AS slots on two separate days were introduced at Addenbrooke's Hospital, Cambridge. The weekly numbers of total prostate MRIs and AS cases recorded 15 months before and after the change (Groups 1 and 2, respectively). An intergroup variation in the weekly scan numbers was assessed using the coefficient of variance (CV) and mean absolute deviation; the Mann-Whitney test was used for an intergroup comparison of the latter.
In AS patients, a shift from considerable to moderate variation in weekly scan numbers was observed between the two groups (CV, 51.7 and 26.8%, respectively); mean absolute deviation of AS scans also demonstrated a significant decrease in Group 2 (1.28 2.58 in Group 1; < 0.001). No significant changes in the variation in total prostate MRIs were observed, despite a 10% increased workload in Group 2.
A significant reduction in weekly variation of AS cases was demonstrated following the introduction of capped bpMRI slots, which can be used for more accurate long-term planning of MRI workload.
The paper illustrates the potential of introducing capped AS MRI slots using a bp protocol to reduce weekly variation in demand and allow for optimising workflow, which will be increasingly important as the demands on radiology departments increase worldwide.
介绍用于主动监测(AS)前列腺癌患者随访成像的 capped biparametric (bp) MRI 插槽,并评估其对每周 AS 病例数量和总 MRI 工作量变化的影响。
在剑桥的 Addenbrooke's 医院引入了三个 20 分钟的 bpMRI AS 插槽,分别在两天进行。在更改前后的 15 个月内记录每周前列腺 MRI 和 AS 病例的总数(分别为第 1 组和第 2 组)。使用变异系数(CV)和平均绝对偏差评估两组之间每周扫描次数的组间差异;使用 Mann-Whitney 检验对后者进行组间比较。
在 AS 患者中,两组之间每周扫描数量的变化从明显到中度变化(CV 分别为 51.7%和 26.8%);AS 扫描的平均绝对偏差在第 2 组中也显著降低(第 1 组为 1.28-2.58; < 0.001)。尽管第 2 组的工作量增加了 10%,但总前列腺 MRI 的变化没有明显变化。
引入 capped bpMRI 插槽后,AS 病例的每周变化显著减少,这可以更准确地规划 MRI 工作量的长期计划。
本文通过使用 bp 协议引入 capped AS MRI 插槽,展示了减少需求的每周变化并优化工作流程的潜力,这在全球范围内放射科需求增加的情况下将变得越来越重要。