Suppr超能文献

单缝线技术在前交叉韧带移植物准备中提供了与三缝线技术相似的稳定性:猪模型的生物力学体外研究。

The single-suture technique for anterior cruciate ligament graft preparation provides similar stability as a three-suture technique: a biomechanical in vitro study in a porcine model.

机构信息

Department of Orthopedic, Trauma and Plastic Surgery, University of Leipzig, Liebigstraße 20, 04103, Leipzig, Germany.

ZESBO, Zentrum Zur Erforschung Der Stütz- Und Bewegungsorgane, Semmelweisstrasse 14, 04103, Leipzig, Germany.

出版信息

Arch Orthop Trauma Surg. 2020 Apr;140(4):511-516. doi: 10.1007/s00402-020-03350-5. Epub 2020 Jan 24.

Abstract

PURPOSE

Numerous techniques have been described for the tibial-sided graft preparation in anterior cruciate ligament (ACL) reconstruction. The use of less suture material for graft preparation is thought to improve ingrowth and to reduce the risk for infection. At the same time, the suture construct should be strong enough to resist the surgeon's pull during tensioning of the transplant.

METHODS

In total, 39 fresh-frozen procine deep flexor tendons were used and prepared as four-strand grafts. In the three-suture group (n = 19), graft preparation was performed using three tibial-sided sutures, with each tendon end sutured separately. In the one-suture group (n = 20), a modified graft preparation using only one tibial-sided suture was applied. Each sample underwent load-to-failure testing (N) after cyclic pre-loading. To estimate intraoperative tension forces acting on the tibial-sided suture constructs, the maximal tension force of 26 volunteers on such a construct was measured using a load cell.

RESULTS

The biomechanical testing of the two different suture constructs showed a significantly higher load-to-failure for the three-suture group (711 N ± 91 N) compared to the one-suture group (347 N ± 24 N) (p = 0.0001). In both groups, the mode of failure was a tear of the suture in all samples. A failure of the suture-tendon interface was not observed in any case. The median maximal tension force on the construct applied by the 26 volunteers was 134 N (range 73-182 N).

CONCLUSION

The presented single-suture tendon graft preparation resisted to smaller failure loads than the conventional three-suture technique. However, no failures in the suture-tendon interface were seen and the failure loads observed were far beyond the tension forces that can be expected intraoperatively. Hence, the single-suture graft preparation technique may be a valuable alternative to the conventional technique.

摘要

目的

在前交叉韧带(ACL)重建中,已经描述了许多胫骨侧移植物制备技术。人们认为,使用较少的缝线材料进行移植物准备可以促进移植物的生长,并降低感染的风险。同时,缝线结构应该足够强大,以抵抗外科医生在拉紧移植物时的拉力。

方法

总共使用了 39 个新鲜冷冻的猪深屈肌腱,并将其制备成四股移植物。在三缝线组(n=19)中,使用三根胫骨侧缝线进行移植物准备,每根肌腱末端单独缝合。在单缝线组(n=20)中,应用了一种改良的单缝线胫骨侧移植物准备方法。每个样本在循环预加载后进行失效负载测试(N)。为了估计作用于胫骨侧缝线结构的术中张力力,使用测力传感器测量了 26 名志愿者在这种结构上的最大张力力。

结果

两种不同缝线结构的生物力学测试显示,三缝线组的失效负载明显高于单缝线组(711 N±91 N 比 347 N±24 N)(p=0.0001)。在两组中,所有样本的失效模式均为缝线撕裂。在任何情况下都没有观察到缝线-肌腱界面的失效。26 名志愿者施加在结构上的最大张力力中位数为 134 N(范围 73-182 N)。

结论

与传统的三缝线技术相比,所提出的单缝线肌腱移植物准备方法抵抗失效负载的能力较小。然而,没有观察到缝线-肌腱界面的失效,并且观察到的失效负载远远超过术中可预期的张力力。因此,单缝线移植物准备技术可能是传统技术的一种有价值的替代方法。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4782/7109177/8e9fbd2508f1/402_2020_3350_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验