Comparison of Surgical Outcomes Between Standard and Elevated-Rim Highly Cross-Linked Polyethylene Acetabular Liners in Primary Total Hip Arthroplasty With Minimum 15-Year Follow-Up: Single-Center, Retrospective Cohort Study.

机构信息

Department of Orthopaedic Surgery, Pusan National University Yangsan Hospital, Yangsan, South Korea.

Department of Orthopaedic Surgery, Bio-medical Research Institute, Pusan National University Hospital, Busan, South Korea.

出版信息

J Arthroplasty. 2020 May;35(5):1290-1296. doi: 10.1016/j.arth.2019.12.026. Epub 2019 Dec 27.

Abstract

BACKGROUND

The aims of the present study are to (1) conduct the longest-to-date follow-up wear analysis of the highly cross-linked polyethylene acetabular liners, (2) assess the incidence of femoral and acetabular osteolysis, and (3) compare the surgical outcomes between standard and elevated-rim acetabular liners in primary total hip arthroplasty (THA).

METHODS

In this retrospective cohort study, we evaluated 112 primary THAs performed by a single experienced arthroplasty surgeon at our institution between March 2000 and December 2003. Patients were classified based on the type of acetabular liner used: standard or elevated-rim liner. For evaluation of surgical outcomes, the following data were collected: acetabular cup position (anteversion and inclination), wear rate (linear and volumetric), presence of osteolysis, history of reoperation (all-cause and wear-related), complications (deep joint infection, dislocation, and periprosthetic fracture), and Harris hip score at last follow-up.

RESULTS

Linear and volumetric wear rates were 0.028 mm/y (0.000-0.145 mm/y) and 11.641 mm/y (0.000-70.000 mm/y) in the standard group and 0.026 mm/y (0.000-0.094mm/y) and 9.706 mm/y (0.000-33.000 mm/y) in the elevated-rim group, respectively. These rates were not significantly different between groups. One case of osteolysis was confirmed in the standard group, whereas no osteolysis was observed in the elevated-rim group.

CONCLUSION

We suggest that elevated-rim highly cross-linked polyethylene acetabular liners might be a good implant option that can be used safely.

摘要

背景

本研究旨在:(1)对超高交联聚乙烯髋臼衬垫进行迄今为止最长时间的随访磨损分析;(2)评估股骨和髋臼骨溶解的发生率;(3)比较标准和高边髋臼衬垫在初次全髋关节置换术中的手术效果。

方法

在这项回顾性队列研究中,我们评估了 2000 年 3 月至 2003 年 12 月期间,由本机构一位经验丰富的关节置换外科医生进行的 112 例初次全髋关节置换术。患者根据髋臼衬垫的类型进行分类:标准或高边衬垫。为了评估手术效果,我们收集了以下数据:髋臼杯位置(前倾角和倾斜角)、磨损率(线性和体积)、骨溶解情况、翻修史(所有原因和与磨损相关)、并发症(深部关节感染、脱位和假体周围骨折)以及末次随访时的 Harris 髋关节评分。

结果

标准组的线性和体积磨损率分别为 0.028mm/y(0.000-0.145mm/y)和 11.641mm/y(0.000-70.000mm/y),高边组分别为 0.026mm/y(0.000-0.094mm/y)和 9.706mm/y(0.000-33.000mm/y)。两组之间的这些速率没有显著差异。标准组确认有 1 例骨溶解,而高边组未见骨溶解。

结论

我们建议高边超高交联聚乙烯髋臼衬垫可能是一种安全的植入物选择。