Suppr超能文献

Quantification of Meloxicam in Human Plasma Using Ionic Liquid-Based Ultrasound-Assisted In Situ Solvent Formation Microextraction Followed by High-Performance Liquid Chromatography.

作者信息

Zeeb Mohsen, Farahani Hadi, Mirza Behrooz, Papan Mohammad Kazem

机构信息

Department of Applied Chemistry, Faculty of Science, Islamic Azad University, South Tehran Branch, Pirouzi st., Dehhaghi st., PO Box 1777613651, Tehran, Iran.

Research Institute of Petroleum Industry (RIPI), West Blvd. of Azadi Sport Complex, PO Box 1485733111, Iran.

出版信息

J Chromatogr Sci. 2018 May 1;56(5):443-451. doi: 10.1093/chromsci/bmy012.

Abstract

A robust extraction method against the variations of sample ionic strength viz. ionic liquid-based ultrasound-assisted in situ solvent formation microextraction (IL-UA-ISFME) was coupled for the first time with high-performance liquid chromatography-ultraviolet detection (HPLC-UV), and successfully used as a more sustainable approach for the determination of meloxicam (MEL) in human plasma. Herein, a hydrophobic IL (1-butyl-3-methylimidazolium hexafluorophosphate) was formed by adding a hydrophilic IL (1-butyl-3-methylimidazolium tetrafluoroborate) to aqueous sample solution containing an ion-exchange reagent (sodium hexafluorophosphate). The target analyte was transferred into the IL medium while the extraction solvent was completely dispersed into the sample using ultrasonic irradiation and then, the settled enriched phase was injected to HPLC. Firstly, main factors affecting the microextraction performance were evaluated and optimized. The linearity was in the range of 5-1,500 ng mL-1 with regression coefficient corresponding to 0.997. Limits of detection (LOD; signal-to-noise ratio (S/N) = 3) and quantification (LOQ, S/N = 10) were 1 and 5 ng mL-1, respectively. An acceptable recovery range of 82.1-93.6% and satisfactory intra-assay (3.6-4.8%, n = 6) and inter-assay (3.3-5.1%, n = 9) precision as well as remarkable sample clean up exhibited good efficiency of the method. The freeze-thaw stability study was performed for samples and standard solutions. To study the applicability of the proposed method, it was employed for the determination of MEL in human plasma after oral administration of the drug and some pharmacokinetic data were achieved. The technique proved to be accurate and reliable for the screening intentions.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验