Department of Prosthodontics, Omsk State Medical University, Omsk 644099, Russia.
Central Research Institute of Dentistry and Maxillofacial Surgery, Moscow 119021, Russia.
Int J Environ Res Public Health. 2020 Feb 3;17(3):933. doi: 10.3390/ijerph17030933.
: To compare the aspect of the reproduction accuracy in studied methods of determination of the (CR) of jaws using the digital research methods. The methods used were bilateral manipulation by P.E. Dawson, frontal deprogrammer, leaf gauge, and intraoral device for recording of Gothic arch angle. : To determine the reproduction accuracy of the centric relation of jaws, we examined 5 patients with intact dentition in a prosthetic dentistry clinic (first class in Angle's system). For each method, 20 registrations of the centric jaw relation were carried out by one operator. The breaks between definitions were 30 minutes. A total of 400 CR recording operations were carried out (400 records of CR). In order to study the reproducibility of CR determination methods, 200 recorded mandible positions were analyzed by means of an analog-to-digital method (a macro kit Canon 650D, Canon 60 mm macro IS USM f2.8, Canon macro ring MR-14 EX and the computer program Adobe Photoshop) to assess the first occlusal contact obtained in the CR of jaws, while the other 200 were analyzed by means of a digital method (the computer program Avantis for 3D modeling, Prime as a laboratory 3D scanner (DOF), and Trios as an intraoral scanner (3Shape)) to assess the spatial position of the mandible in the CR. Statistical analysis was carried out using STATISTICA-10. In all statistical analysis procedures, the critical significance level p was assumed to be 0.05. : In the study of the data by means of the computer program Avanti 3D, the reproducibility of the mandible position in the CR reached 0.119 ± 0.012 mm for frontal deprogrammer, 0.225 ± 0.028, ≤ 0.05 for bilateral manipulation by Dawson P.E., 0.207 ± 0.02, ≤ 0.05 for leaf gauge, and 0.120 ± 0,013, ≤ 0.05 using an intraoral device for recording the Gothic arch angle. The analog-to-digital method showed an identical tendency for reproduction of the mandible position. : The digital analysis we made using the Avantis 3D program showed, with high confidence, that the maximum reproducibility of the CR position was reached by using our own design frontal deprogrammer and the device for recording Gothic arch angle.
为了比较使用数字研究方法确定颌骨(CR)的研究方法在再现精度方面的差异。所使用的方法有 P.E. Dawson 的双侧操作、前牙去代偿器、牙弓描记器和记录哥特弓角度的口内装置。为了确定颌骨的正中关系的再现精度,我们在一个修复牙科诊所检查了 5 名具有完整牙列的患者(Angle 系统中的 1 类)。对于每种方法,由一名操作员进行了 20 次颌骨正中关系的记录。定义之间的间隔为 30 分钟。共进行了 400 次 CR 记录操作(400 次 CR 记录)。为了研究 CR 确定方法的再现性,通过模拟-数字方法(佳能 650D 模拟数字套件、佳能 60mm 微距 IS USM f2.8、佳能微距环 MR-14 EX 和 Adobe Photoshop 计算机程序)分析了 200 个记录的下颌位置,以评估在颌骨的 CR 中获得的初次咬合接触,而另外 200 个通过数字方法(3D 建模计算机程序 Avantis、Prime 实验室 3D 扫描仪(DOF)和 Trios 口内扫描仪(3Shape))进行分析,以评估 CR 中下颌的空间位置。使用 STATISTICA-10 进行了统计分析。在所有的统计分析过程中,假设临界显著水平 p 为 0.05。在使用 Avanti 3D 计算机程序研究数据的过程中,前牙去代偿器的下颌位置再现性达到 0.119 ± 0.012mm,双侧操作 P.E. Dawson 为 0.225 ± 0.028, ≤ 0.05,牙弓描记器为 0.207 ± 0.02, ≤ 0.05,记录哥特弓角度的口内装置为 0.120 ± 0.013, ≤ 0.05。模拟-数字方法显示出对下颌位置再现的相同趋势。我们使用 Avantis 3D 程序进行的数字分析,非常有信心地表明,使用我们自己设计的前牙去代偿器和记录哥特弓角度的装置可以达到 CR 位置的最大再现性。