Suppr超能文献

Woven EndoBridge 单层治疗颅内动脉瘤的系统评价和荟萃分析。

A systematic review and meta-analysis of Woven EndoBridge single layer for treatment of intracranial aneurysms.

机构信息

Department of Radiology, St. Antonius Ziekenhuis, Nieuwegein, the Netherlands.

Department of Radiology, Amsterdam UMC, Amsterdam, the Netherlands.

出版信息

Interv Neuroradiol. 2020 Aug;26(4):455-460. doi: 10.1177/1591019920904421. Epub 2020 Feb 6.

Abstract

BACKGROUND AND PURPOSE

The Woven EndoBridge is an intrasaccular device for the treatment of intracranial aneurysms. The first generation consisted of a high-profile double-layer braid. This review aims to evaluate the outcomes of the new generation low-profile Woven EndoBridge single layer device for intracranial aneurysm treatment.

METHODS

A systematic review was conducted with Medline, Embase, and Web of Science Conference Proceedings databases. The search strategy provided 589 articles, 15 articles were included.

RESULTS

Fifteen articles were identified reporting the use of Woven EndoBridge single-layer devices in 963 aneurysms, mostly wide-necked bifurcation aneurysms. Procedural aneurysm rupture was reported in 8 of 963 patients (0.83%; 95%CI 0.39-1.66%) and thromboembolic events in 54 of 963 patients (5.61%, 95CI 4.31-7.26%). Cumulative morbidity was 2.85% (27/949, 95%CI 1.95-4.12%) and mortality 0.93% (9/963, 95%CI 0.46-1.80%). The overall rate of adequate aneurysm occlusion at last follow-up was 83.3% (613/736; 95%CI 80.4-85.8%). Retreatment was reported in 38 aneurysms in eight studies with 450 aneurysms with follow-up (38/450; 8.4%, 95CI 6.2-11.4%). In 12 studies comprising 644 aneurysms with follow-up, rebleeds occurred in three patients in three studies with mean follow-up between 3.3 and 14.4 months (0.47%, 95%CI 0.09-1.43%).

CONCLUSION

Woven EndoBridge single-layer is a promising new low-profile device especially for wide-neck bifurcation aneurysms, both ruptured and unruptured. No antiplatelet medication is needed which is a great advantage, especially in ruptured aneurysms. Efficacy and safety compare favorably with (stent-assisted) coiling. However, no direct comparison with other treatments is available as yet.

摘要

背景与目的

Woven EndoBridge 是一种用于治疗颅内动脉瘤的腔内装置。第一代由一个高轮廓的双层编织物组成。本综述旨在评估新一代低轮廓 Woven EndoBridge 单层装置治疗颅内动脉瘤的结果。

方法

通过 Medline、Embase 和 Web of Science Conference Proceedings 数据库进行系统评价。搜索策略提供了 589 篇文章,纳入了 15 篇文章。

结果

15 篇文章报道了 963 例使用 Woven EndoBridge 单层装置的病例,大多数为宽颈分叉部动脉瘤。963 例患者中有 8 例(0.83%;95%CI 0.39-1.66%)出现术中动脉瘤破裂,54 例(5.61%,95%CI 4.31-7.26%)发生血栓栓塞事件。累积发病率为 2.85%(27/949,95%CI 1.95-4.12%),死亡率为 0.93%(9/963,95%CI 0.46-1.80%)。末次随访时,动脉瘤完全闭塞率为 83.3%(613/736;95%CI 80.4-85.8%)。8 项研究中 38 例动脉瘤在 3 项研究中进行了再治疗,共纳入 450 例有随访的动脉瘤(38/450;8.4%,95%CI 6.2-11.4%)。在 12 项包含 644 例有随访的动脉瘤的研究中,3 项研究中有 3 例患者再出血,平均随访时间为 3.3 至 14.4 个月(0.47%,95%CI 0.09-1.43%)。

结论

Woven EndoBridge 单层是一种很有前途的新型低轮廓装置,特别适用于宽颈分叉部动脉瘤,包括破裂和未破裂的动脉瘤。不需要抗血小板药物治疗,这是一个很大的优势,尤其是在破裂的动脉瘤中。疗效和安全性与(支架辅助)弹簧圈治疗相当。然而,目前还没有与其他治疗方法的直接比较。

相似文献

引用本文的文献

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验