Rajendran Praveenbalaji, Sahu Samiran, Dienzo Rhonnie Austria, Pramanik Manojit
School of Chemical and Biomedical Engineering, Nanyang Technological University, 62 Nanyang drive, Singapore, Singapore.
J Biophotonics. 2020 Jun;13(6):e201960162. doi: 10.1002/jbio.201960162. Epub 2020 Mar 20.
Intracranial hypotension (IH) is a pathophysiological condition of reduced intracranial pressure caused by low cerebrospinal fluid (CSF) volume due to dural injuries from lumbar puncture, surgery, or trauma. Understanding the prognosis of IH in small animal models is important to gain insights on the complications associated with it such as orthostatic headache, cerebral venous thrombosis, coma, and so forth. Photoacoustic tomography (PAT) offers a novel and cost-effective way to perceive and detect IH in small animal models. In this study, a pulsed laser diode (PLD)-based PAT imaging system was used to examine the changes in the venous sinuses of the rat brain due to IH, induced through CSF extraction. After the CSF extraction, an increase in the sagittal sinus area by ~30% and width by 40% ± 5% was observed. These results provide supportive evidence that the PLD-PAT can be employed for detecting changes in sagittal sinus due to IH in rat model.
颅内低压(IH)是一种病理生理状态,由于腰椎穿刺、手术或创伤导致硬脑膜损伤,引起脑脊液(CSF)量减少,进而导致颅内压降低。了解小动物模型中IH的预后对于深入了解与之相关的并发症(如直立性头痛、脑静脉血栓形成、昏迷等)非常重要。光声断层扫描(PAT)为在小动物模型中感知和检测IH提供了一种新颖且经济高效的方法。在本研究中,基于脉冲激光二极管(PLD)的PAT成像系统被用于检查通过脑脊液抽取诱导的IH导致的大鼠脑静脉窦变化。脑脊液抽取后,观察到矢状窦面积增加约30%,宽度增加40%±5%。这些结果提供了支持性证据,表明PLD-PAT可用于检测大鼠模型中由于IH引起的矢状窦变化。