Institute of Environmental Science and Engineering (IESE), National University of Civil Engineering, Hanoi, Vietnam.
Department of Civil and Environmental Engineering, Seoul National University, Seoul, South Korea.
Environ Sci Pollut Res Int. 2021 Mar;28(10):11928-11941. doi: 10.1007/s11356-020-07977-0. Epub 2020 Feb 19.
This study assessed the performance of rainwater-harvesting systems installed for selected public utilities in the northern provinces of Vietnam where rainwater was collected, stored in stainless steel tanks, and treated with a complex filtration unit and Ultraviolet (UV) disinfection system (full system). Results from an operation of over 5 years show that the untreated rainwater could not be used directly for drinking purposes as it was contaminated with bacteria (total coliforms TC = 200-300 CFU/100 ml, Pseudomonas aeruginosa PA = 40-160 CFU/100 ml), and turbidity = 2-4 NTU. Most of the heavy metals detected were found below the standard limits. Phenol and its derivatives were detected occasionally as higher than the standard value (1 μg/L). After treatment, all parameters met the drinking water standards. The capital costs of the rainwater systems were approximately US$200/m and US$180/m for a full system and simplified system (without complex filtration unit), respectively, while the operation and maintenance (O&M) costs were 3 cents/L and 0.8 cents/L on average for a full system and simplified one, correspondingly.
本研究评估了在越南北部省份为选定公共设施安装的雨水收集系统的性能,这些雨水在那里被收集、储存在不锈钢罐中,并通过复杂的过滤单元和紫外线 (UV) 消毒系统进行处理(全套系统)。超过 5 年的运行结果表明,未经处理的雨水不能直接用于饮用,因为它受到细菌(总大肠菌群 TC = 200-300 CFU/100 ml,铜绿假单胞菌 PA = 40-160 CFU/100 ml)和浊度(2-4 NTU)的污染。检测到的大多数重金属含量都低于标准限值。酚类及其衍生物偶尔会被检测到高于标准值(1 μg/L)。经过处理后,所有参数均符合饮用水标准。雨水系统的资本成本约为每立方米 200 美元,全套系统和简化系统(无复杂过滤单元)分别为每立方米 180 美元,而全套系统和简化系统的运行和维护成本平均分别为每升 3 美分和 0.8 美分。