Mendenhall Marcus H, Hudson Lawrence T, Szabo Csilla I, Henins Albert, Cline James P
National Institute of Standards and Technology, 100 Bureau Dr., Gaithersburg MD 20899, USA.
Theiss Research, 7411 Eads Ave, La Jolla CA 92037, USA.
J Phys B At Mol Opt Phys. 2019;52(21). doi: 10.1088/1361-6455/ab45d6.
We present newly measured spectra of the X-ray emission of a molybdenum metal anode subject to electron bombardment, using a very high dispersion silicon double-crystal spectrometer. The measurement includes the dipole-allowed , , and emission lines, based on an energy scale traceable to the Système International (SI) definition of the meter with a systematic uncertainty below Δ = 10. The data are presented as parametrized multi-Lorentzian fits to the results, and as supplementary data with the complete spectrum of each line group, corrected for instrumental effects. The Mo ( ) line energy was in complete statistical agreement with published measurements, and it showed no asymmetry. Other lines showed varying discrepancies with the literature which lie outside the bounds of probable experimental errors.