University Hospital Southampton NHS Foundation Trust, Southampton, United Kingdom.
Laryngoscope. 2021 Jan;131(1):E59-E62. doi: 10.1002/lary.28590. Epub 2020 Feb 28.
The Control of Noise at Work Regulations came into force in Great Britain in 2005, requiring all work environments to be monitored for potentially harmful noise exposure levels. This study evaluated the effectiveness of a number of iPhone phone applications (apps) (Apple, Cupertino, CA) to accurately measure noise exposure, which may prove effective when a specialist-calibrated sound level meter is not readily available.
Suitable apps were identified using the search terms noise and decibel through the App Store (Apple). Apps that were free to download and had at least one rating were included. Apps were evaluated using a calibrated pure tone sound field and a soundproof testing booth. A 3-frequency audiogram (1000 Hz, 2000 Hz, and 4000 Hz) was used at 25 dB, 40 dB, 55 dB, 70 dB, and 85 dB. Linear regression was carried out to assess accuracy.
Nine apps were tested in total, with four out of nine providing a goodness-of-fit coefficient (R value) over 0.9. The most effective app was found to be the NIOSH (National Institute for Occupational Safety and Health) Sound Level Meter (EA LAB, Slovenia) with an R of 0.97. The least effective app was the Decibel Meter With Recorder (Jianhua Ming, China) with an R of 0.62.
This study has shown significant variation in the ability of iPhone apps (Apple) to accurately predict environmental dB levels. However, if the correct app is used, an iPhone represents a relatively reliable means of measuring noise exposure levels when a specialist calibrated sound level meter is not readily available.
NA Laryngoscope, 131:E59-E62, 2021.
2005 年,英国《工作场所噪声控制条例》生效,要求所有工作环境都要监测潜在有害噪声暴露水平。本研究评估了一些 iPhone 手机应用程序(Apps)(Apple,Cupertino,CA)准确测量噪声暴露的有效性,当没有现成的经过专业校准的声级计时,这些应用程序可能会很有效。
通过 App Store(Apple)使用搜索词“noise(噪声)”和“decibel(分贝)”来识别合适的应用程序。下载免费且至少有一个评分的应用程序。使用校准的纯音声场和隔声测试室评估应用程序。在 25dB、40dB、55dB、70dB 和 85dB 处使用 3 个频率听力图(1000Hz、2000Hz 和 4000Hz)。进行线性回归以评估准确性。
共测试了 9 个应用程序,其中 9 个中有 4 个提供了拟合优度系数(R 值)超过 0.9。最有效的应用程序是 NIOSH(美国职业安全与健康研究所)声级计(EA LAB,斯洛文尼亚),R 值为 0.97。最不准确的应用程序是带有记录器的分贝计(Jianhua Ming,中国),R 值为 0.62。
本研究表明,iPhone 应用程序(Apple)准确预测环境 dB 水平的能力存在显著差异。然而,如果使用正确的应用程序,当没有现成的经过专业校准的声级计时,iPhone 代表了一种相对可靠的测量噪声暴露水平的方法。
无。喉镜,131:E59-E62,2021。