Department of Physiotherapy, Faculty of Health, Universidad Camilo José Cela, Villanueva de la Cañada, 28692 Madrid, Spain.
VALTRADOFI Research Group, Department of Physiotherapy, Faculty of Health, Universidad Camilo José Cela, Villanueva de la Cañada, 28692 Madrid, Spain.
Sensors (Basel). 2022 Mar 18;22(6):2365. doi: 10.3390/s22062365.
Static posturography assessed with force platforms is a procedure used to obtain objective estimates related to postural adjustments. However, controlling multiple intrinsic and extrinsic factors influencing the diagnostic accuracy is essential to obtain reliable measurements and recommend its use with clinical or research purposes. We aimed to analyze how different environmental acoustic conditions affect the test−retest reliability and to analyze the most appropriate number of trials to calculate a valid mean average score. A diagnostic accuracy study was conducted enrolling 27 healthy volunteers. All procedures were taken considering consistent device settings, posture, feet position, recording time, and illumination of the room. Three trials were recorded in a silent environment (35−40 dB) and three trials were recorded in a noisy environment (85−90 dB). Results showed comparable reliability estimates for both acoustic conditions (ICC = 0.453−0.962 and 0.621−0.952), but silent conditions demonstrated better sensitivity to changes (MDC = 13.6−76%). Mean average calculations from 2 and 3 trials showed no statistically significant differences (p > 0.05). Cross-sectional studies can be conducted under noisy or silent conditions as no significantly different scores were obtained (p > 0.05) and ICC were comparable (except oscillation area). However, longitudinal studies should consider silent conditions as they demonstrated better sensitivity to real changes not derived from measurement errors.
静态平衡仪评估采用测力平台,是一种获取与姿势调整相关的客观估计的程序。然而,控制影响诊断准确性的多个内在和外在因素对于获得可靠的测量结果至关重要,并建议将其用于临床或研究目的。我们旨在分析不同环境声学条件如何影响测试-再测试的可靠性,并分析计算有效平均分数的最合适试验次数。一项诊断准确性研究纳入了 27 名健康志愿者。所有程序均在考虑设备设置、姿势、脚的位置、记录时间和房间照明一致的情况下进行。在安静环境(35-40 dB)下记录了三次试验,在嘈杂环境(85-90 dB)下记录了三次试验。结果表明,两种声学条件下的可靠性估计值相当(ICC = 0.453-0.962 和 0.621-0.952),但安静条件下对变化的敏感性更好(MDC = 13.6-76%)。从 2 次和 3 次试验得出的平均平均值计算结果没有统计学差异(p > 0.05)。可以在嘈杂或安静的条件下进行横断面研究,因为没有获得显著不同的分数(p > 0.05),并且 ICC 相当(除了摆动面积)。然而,纵向研究应考虑安静条件,因为它们对源于测量误差的真实变化具有更好的敏感性。