Suppr超能文献

Turbo 自旋回波弥散加权成像与单次激发回波平面弥散加权成像的比较:在鉴别导管原位癌和浸润性导管癌时的图像质量和诊断性能。

Turbo Spin-echo Diffusion-weighted Imaging Compared with Single-shot Echo-planar Diffusion-weighted Imaging: Image Quality and Diagnostic Performance When Differentiating between Ductal Carcinoma in situ and Invasive Ductal Carcinoma.

机构信息

Department of Diagnostic Radiology, Tohoku University Graduate School of Medicine.

Department of Surgical Oncology, Tohoku University Graduate School of Medicine.

出版信息

Magn Reson Med Sci. 2021 Mar 1;20(1):60-68. doi: 10.2463/mrms.mp.2019-0195. Epub 2020 Mar 6.

Abstract

PURPOSE

To compare the image quality between turbo spin-echo (TSE)-diffusion weighted imaging (DWI) and single-shot echo-planar imaging (EPI)-DWI, and to verify the diagnostic performance of the apparent diffusion coefficient (ADC) parameters of the two techniques by using histogram analysis in terms of differentiation between ductal carcinoma in situ (DCIS) and invasive ductal carcinoma (IDC) lesions.

METHODS

Ninety-four women with 94 lesions diagnosed as breast cancer by surgery underwent IRB-approved preoperative magnetic resonance imaging, including TSE and EPI-DWI with b-values of 50 and 850 s/mm. Twenty lesions were identified as DCIS and 74 as IDC. Image quality [signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and geometric distortion] was evaluated quantitatively and compared between the TSE and EPI-DWI. A histogram analysis of the entire tumor voxel-based ADC data was performed, and the 10th, 25th, 50th, 75th, and 90th percentile values of each technique were compared between DCIS and IDC lesions.

RESULTS

The SNR and CNR of TSE-DWI were significantly higher than those of EPI-DWI (P < 0.0001 and < 0.0001). The geometric distortion of TSE-DWI was significantly lower than that of EPI-DWI (P < 0.0001). In TSE-DWI, the 10th, 25th, 50th, and 75th percentile values were significantly different between the DCIS and IDC lesions (P = 0.0010, 0.0004, 0.0008, and 0.0044, respectively). In EPI-DWI, the 50th and 75th percentile values were significantly different between the two groups (P = 0.0009 and 0.0093). There was no significant difference in the area under the curve of the receiver operating characteristic analysis of the 10th, 25th, 50th, and 75th percentile values of TSE-DWI, and the 50th and 75th percentile values of EPI-DWI (P = 0.29).

CONCLUSION

The image quality of TSE-DWI was better than that of EPI-DWI. DCIS lesions were distinguished from IDC lesions with a wider range of percentile values in TSE-DWI than in EPI-DWI, although diagnostic performance was not significantly different between the techniques.

摘要

目的

比较涡轮自旋回波(TSE)-扩散加权成像(DWI)与单次激发回波平面成像(EPI)-DWI 的图像质量,并通过直方图分析验证两种技术的表观扩散系数(ADC)参数在区分导管原位癌(DCIS)和浸润性导管癌(IDC)病变方面的诊断性能。

方法

94 名经手术确诊为乳腺癌的女性接受了经机构审查委员会批准的术前磁共振成像检查,包括 TSE 和 EPI-DWI,b 值分别为 50 和 850 s/mm。20 个病灶被确定为 DCIS,74 个为 IDC。定量评估 TSE 和 EPI-DWI 的图像质量(信噪比(SNR)、对比噪声比(CNR)和几何变形),并进行比较。对整个肿瘤体素 ADC 数据进行直方图分析,比较两种技术在 DCIS 和 IDC 病变中第 10、25、50、75 和 90 百分位数值的差异。

结果

TSE-DWI 的 SNR 和 CNR 明显高于 EPI-DWI(P < 0.0001 和 < 0.0001)。TSE-DWI 的几何变形明显低于 EPI-DWI(P < 0.0001)。在 TSE-DWI 中,第 10、25、50 和 75 百分位数值在 DCIS 和 IDC 病变之间有显著差异(P = 0.0010、0.0004、0.0008 和 0.0044)。在 EPI-DWI 中,两组间第 50 和 75 百分位数值有显著差异(P = 0.0009 和 0.0093)。TSE-DWI 的第 10、25、50 和 75 百分位数值和 EPI-DWI 的第 50 和 75 百分位数值的受试者工作特征分析曲线下面积无显著差异(P = 0.29)。

结论

TSE-DWI 的图像质量优于 EPI-DWI。与 EPI-DWI 相比,TSE-DWI 中 DCIS 病变与 IDC 病变的区分范围更宽,尽管两种技术的诊断性能没有显著差异。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8efb/7952202/f249771f6657/mrms-20-060-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验