Suppr超能文献

结合增强磁共振和弥散加权成像阅读适应“乳腺影像报告和数据系统”的多参数 3-T 成像乳腺病变。

Combined contrast-enhanced magnetic resonance and diffusion-weighted imaging reading adapted to the "Breast Imaging Reporting and Data System" for multiparametric 3-T imaging of breast lesions.

机构信息

Department of Radiology, Molecular and Gender Imaging, Medical University Vienna, Vienna, Austria.

出版信息

Eur Radiol. 2013 Jul;23(7):1791-802. doi: 10.1007/s00330-013-2771-8. Epub 2013 Mar 16.

Abstract

OBJECTIVE

To develop and assess a combined reading for contrast-enhanced magnetic resonance (CE-MRI) and diffusion weighted imaging (DWI) adapted to the BI-RADS for multiparametric MRI of the breast at 3 T.

METHODS

A total of 247 patients with histopathologically verified breast lesions were included in this IRB-approved prospective study. All patients underwent CE-MR and DWI at 3 T. MRIs were classified according to BI-RADS and assessed for apparent diffusion coefficient (ADC) values. A reading method that adapted ADC thresholds to the assigned BI-RADS classification was developed. Sensitivity, specificity, diagnostic accuracy and the area under the curve were calculated. BI-RADS-adapted reading was compared with previously published reading methods in the same population. Inter- and intra-reader variability was assessed.

RESULTS

Sensitivity of BI-RADS-adapted reading was not different from the high sensitivity of CE-MRI (P = 0.4). BI-RADS-adapted reading maximised specificity (89.4 %), which was significantly higher compared with CE-MRI (P < 0.001). Previous reading methods did not perform as well as the BI-RADS method except for a logistic regression model. BI-RADS-adapted reading was more sensitive in non-mass-like enhancements (NMLE) and was more robust to inter- and intra-reader variability.

CONCLUSION

Multiparametric 3-T MRI of the breast using a BI-RADS-adapted reading is fast, simple to use and significantly improves the diagnostic accuracy of breast MRI. KEYPOINTS : • Multiparametric breast 3-T MRI with BI-RADS-adapted reading improves diagnostic accuracy. • BI-RADS-adapted reading of CE-MRI and DWI is based on established reporting guidelines. • BI-RADS-adapted reading is fast and easy to use in routine clinical practice. • BI-RADS-adapted reading is robust to intra- and inter-reader variability.

摘要

目的

开发并评估一种联合阅读方法,用于适应 BI-RADS 的 3T 多参数乳腺磁共振成像(MRI)的对比增强磁共振(CE-MRI)和弥散加权成像(DWI)。

方法

本项经机构审查委员会批准的前瞻性研究共纳入 247 例经组织病理学证实的乳腺病变患者。所有患者均在 3T 行 CE-MRI 和 DWI 检查。根据 BI-RADS 对 MRI 进行分类,并评估表观扩散系数(ADC)值。开发了一种将 ADC 阈值适应于分配 BI-RADS 分类的阅读方法。计算了敏感性、特异性、诊断准确性和曲线下面积。将 BI-RADS 适应的阅读与同一人群中先前发表的阅读方法进行比较。评估了读者间和读者内的可变性。

结果

BI-RADS 适应的阅读的敏感性与 CE-MRI 的高敏感性无差异(P=0.4)。BI-RADS 适应的阅读最大程度地提高了特异性(89.4%),与 CE-MRI 相比显著更高(P<0.001)。除了逻辑回归模型外,先前的阅读方法不如 BI-RADS 方法表现良好。BI-RADS 适应的阅读在非肿块样增强(NMLE)中更敏感,并且对读者间和读者内的可变性更稳健。

结论

使用 BI-RADS 适应的阅读的乳腺 3T 多参数 MRI 快速、易于使用,并显著提高了乳腺 MRI 的诊断准确性。

关键点

• 基于 BI-RADS 的乳腺 3-T MRI 联合阅读可提高诊断准确性。

• BI-RADS 适应的 CE-MRI 和 DWI 阅读基于既定的报告指南。

• BI-RADS 适应的阅读在常规临床实践中快速且易于使用。

• BI-RADS 适应的阅读对读者间和读者内的可变性具有稳健性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验