Muto Tetsuya, Machida Shigeki
Department of Ophthalmology, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan.
Clin Ophthalmol. 2020 Mar 3;14:625-634. doi: 10.2147/OPTH.S243370. eCollection 2020.
To compare the effects of 30-gauge versus 32-gauge needles on vitreous reflux (VR) frequency and intraocular pressure (IOP) following first-time intravitreal aflibercept injections.
Overall, 116 patients (116 eyes) who received intravitreal injections using 30-gauge needles and 104 patients (104 eyes) who received the same injection using 32-gauge needles were reviewed. The medical records of 116 patients who each received an intravitreal injection using a 30-gauge needle (median age: 67.5 ± 13.9 years) and 104 patients who each received the same injection using a 32-gauge needle (median age: 66. 3 ± 10.6 years) from January 2015 to June 2019 were compared.
No significant difference in the frequency of VR was observed between patients injected using 30-gauge needles (38/116) and patients injected using 32-gauge needles (31/104, = 0.64). There were no significant differences in the VR rates of patients with phakic and pseudophakic eyes between those injected using 30-gauge ( = 0.94) or 32-gauge needles ( = 0.77). Axial length did not significantly differ between patients with and without VR when injected using 30-gauge ( = 0.89) and with 32-gauge needles ( = 0.69). IOP immediately after injection was significantly higher in patients injected using 30-gauge needles than in patients injected using 32-gauge needles ( < 0.01).
VR frequency was not correlated with needle size, lens status, or axial length. Patients receiving injections using 30-gauge needles had higher IOP immediately after intravitreal injection.
比较30号与32号针头在首次玻璃体内注射阿柏西普后对玻璃体反流(VR)频率和眼压(IOP)的影响。
回顾了总共116例使用30号针头进行玻璃体内注射的患者(116只眼)和104例使用32号针头进行相同注射的患者(104只眼)。比较了2015年1月至2019年6月期间116例使用30号针头(中位年龄:67.5±13.9岁)进行玻璃体内注射的患者和104例使用32号针头(中位年龄:66.3±10.6岁)进行相同注射的患者的病历。
使用30号针头注射的患者(38/116)与使用32号针头注射的患者(31/104,P=0.64)之间,VR频率无显著差异。在使用30号(P=0.94)或32号针头(P=0.77)注射的有晶状体眼和人工晶状体眼患者的VR发生率上,无显著差异。使用30号(P=0.89)和32号针头(P=0.69)注射时,有VR和无VR患者的眼轴长度无显著差异。使用30号针头注射的患者注射后即刻的IOP显著高于使用32号针头注射的患者(P<0.01)。
VR频率与针头尺寸、晶状体状态或眼轴长度无关。接受30号针头注射的患者在玻璃体内注射后即刻IOP较高。