Suppr超能文献

随机对照试验评估羟基磷灰石涂层对全髋关节置换术后骨密度丢失和骨代谢的影响:采用 F-氟正电子发射断层扫描和双能 X 射线吸收法。

Influence of Hydroxyapatite Coating for the Prevention of Bone Mineral Density Loss and Bone Metabolism after Total Hip Arthroplasty: Assessment Using F-Fluoride Positron Emission Tomography and Dual-Energy X-Ray Absorptiometry by Randomized Controlled Trial.

机构信息

Department of Orthopedic Surgery, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama, Japan.

Department of Orthopaedic Surgery, Yokohama City University Medical Center, 4-57 Urafunecho, Minami-ku, Yokohama, Japan.

出版信息

Biomed Res Int. 2020 Feb 22;2020:4154290. doi: 10.1155/2020/4154290. eCollection 2020.

Abstract

BACKGROUND

Hydroxyapatite- (HA-) coated implants tend to achieve good osteoinductivity and stable clinical results; however, the influence of the coating on the prevention of bone mineral density (BMD) loss around the implant is unclear. The purpose of this randomized controlled trial was to evaluate the effectiveness of HA-coated implants for preventing BMD loss and to determine the status of bone remodeling after total hip arthroplasty (THA), making comparisons with non-HA-coated implants.

METHODS

A total of 52 patients who underwent primary THA were randomly allocated to HA and non-HA groups. BMD was measured by dual-energy X-ray absorptiometry (DEXA) at 1 week postoperation to form a baseline measurement, and then 24 weeks and 48 weeks after surgery. The relative change in BMD was evaluated for regions of interest (ROIs) based on the Gruen zone classifications. F-fluoride positron emission tomography (PET) was performed at 24 weeks postsurgery, and the maximum standardized uptake values (SUV) were evaluated in the proximal (HA-coated) and distal (non-HA-coated) areas in both groups.

RESULTS

There were significant differences in BMD loss in ROIs 3 and 6 ( = 0.03), while no significant difference was observed in ROI 7 at either 24 or 48 weeks postsurgery. There was no significant correlation between PET uptake and BMD (24 or 48 weeks) in either group.

CONCLUSION

The influence of a HA coating in terms of BMD preservation is limited. No significant correlation was found between BMD and SUV measured by PET, either with or without the use of a HA coating.

摘要

背景

羟基磷灰石(HA)涂层植入物往往具有良好的成骨诱导性和稳定的临床效果;然而,涂层对预防植入物周围骨密度(BMD)丢失的影响尚不清楚。本随机对照试验的目的是评估 HA 涂层植入物预防 BMD 丢失的有效性,并确定全髋关节置换术(THA)后骨重建的状况,与非 HA 涂层植入物进行比较。

方法

52 例接受初次 THA 的患者被随机分配到 HA 和非 HA 组。术后 1 周通过双能 X 射线吸收法(DEXA)测量 BMD,形成基线测量值,然后在术后 24 周和 48 周进行测量。根据 Gruen 区分类,评估感兴趣区域(ROI)的 BMD 相对变化。术后 24 周行 F-氟代脱氧葡萄糖正电子发射断层扫描(PET),评估两组近侧(HA 涂层)和远侧(非 HA 涂层)区域的最大标准化摄取值(SUV)。

结果

在 ROI 3 和 6 中,BMD 丢失存在显著差异( = 0.03),而在术后 24 或 48 周时,ROI 7 中未观察到显著差异。在两组中,PET 摄取与 BMD(24 或 48 周)均无显著相关性。

结论

HA 涂层对 BMD 保留的影响有限。无论是否使用 HA 涂层,PET 测量的 BMD 与 SUV 之间均未发现显著相关性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6e7d/7060431/eb3560e76384/BMRI2020-4154290.001.jpg

相似文献

本文引用的文献

2
Long-term bone remodelling around 'legendary' cementless femoral stems.“传奇”非骨水泥型股骨柄周围的长期骨重塑
EFORT Open Rev. 2018 Feb 26;3(2):45-57. doi: 10.1302/2058-5241.3.170024. eCollection 2018 Feb.
3
Implant Design in Cementless Hip Arthroplasty.非骨水泥型髋关节置换术中的植入物设计
Hip Pelvis. 2016 Jun;28(2):65-75. doi: 10.5371/hp.2016.28.2.65. Epub 2016 Jun 30.
4
Remodeling of bone tissue around the distal part of Zweymüller stem.Zweymüller柄远端周围骨组织的重塑
Ortop Traumatol Rehabil. 2015 Jul-Aug;17(4):371-80. doi: 10.5604/15093492.1173379.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验