Suppr超能文献

利用双着丝粒染色体畸变构建和验证体外剂量反应校准曲线

CONSTRUCTION AND VALIDATION OF IN VITRO DOSE-RESPONSE CALIBRATION CURVE USING DICENTRIC CHROMOSOME ABERRATION.

作者信息

Mirrezaei Ehsan, Setayeshi Saeed, Zakeri Farideh, Baradaran Samaneh

机构信息

Department of Energy Engineering and Physics, Amirkabir University of Technology (Tehran Polytechnic), Tehran 11365-3486, Iran.

Nuclear Science and Technology Research Institute, Tehran 14155-1339, Iran.

出版信息

Radiat Prot Dosimetry. 2020 Jul 13;189(2):198-204. doi: 10.1093/rpd/ncaa031.

Abstract

Cytogenetic biodosimetry is a well-known method for quantifying the absorbed dose based on measuring biological radiation effects. To correlate the induced chromosomal abberrations with the absorbed dose of the individuals, a reliable dose-response calibration curve should be established. This study aimed to use frequencies and distributions of radiation-induced dicentric chromosome aberrations to develop a standard dose-response calibration curve. Peripheral blood samples taken from six male donors irradiated by an X-ray generator up to 4 Gy were studied. Three different blood samples were irradiated by known doses, then scored blindly for verification of the proposed calibration curve. Dose estimation was also carried out for three real overexposed cases. The results showed good accordance with the other published curves. The constructed dose-response curve provides a reliable tool for biological dosimetry in accidental or occupational radiation exposures.

摘要

细胞遗传学生物剂量测定法是一种基于测量生物辐射效应来量化吸收剂量的知名方法。为了将诱导的染色体畸变与个体的吸收剂量相关联,应建立可靠的剂量反应校准曲线。本研究旨在利用辐射诱导的双着丝粒染色体畸变的频率和分布来制定标准剂量反应校准曲线。对从6名受X射线发生器照射至4 Gy的男性供体采集的外周血样本进行了研究。对三个不同的血样进行已知剂量的照射,然后进行盲法评分以验证所提出的校准曲线。还对三个实际过度暴露病例进行了剂量估计。结果与其他已发表的曲线显示出良好的一致性。构建的剂量反应曲线为意外或职业辐射暴露中的生物剂量测定提供了可靠工具。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验