Suppr超能文献

建立用于双着丝粒染色体畸变的参考剂量-反应校准曲线以评估沙特阿拉伯的意外辐射暴露。

Establishing a Reference Dose-Response Calibration Curve for Dicentric Chromosome Aberrations to Assess Accidental Radiation Exposure in Saudi Arabia.

作者信息

Alsbeih Ghazi A, Al-Hadyan Khaled S, Al-Harbi Najla M, Bin Judia Sara S, Moftah Belal A

机构信息

Radiation Biology Section, Biomedical Physics Department, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia.

College of Medicine, Alfaisal University, Riyadh, Saudi Arabia.

出版信息

Front Public Health. 2020 Dec 15;8:599194. doi: 10.3389/fpubh.2020.599194. eCollection 2020.

Abstract

In cases of nuclear and radiological accidents, public health and emergency response need to assess the magnitude of radiation exposure regardless of whether they arise from disaster, negligence, or deliberate act. Here we report the establishment of a national reference dose-response calibration curve (DRCC) for dicentric chromosome (DC), prerequisite to assess radiation doses received in accidental exposures. Peripheral blood samples were collected from 10 volunteers (aged 20-40 years, median = 29 years) of both sexes (three females and seven males). Blood samples, cytogenetic preparation, and analysis followed the International Atomic Energy Agency EPR-Biodosimetry 2011 report. Irradiations were performed using 320 kVp X-rays. Metafer system was used for automated and assisted (elimination of false-positives and inclusion of true-positives) metaphases findings and DC scoring. DC yields were fit to a linear-quadratic model. Results of the assisted DRCC showed some variations among individuals that were not statistically significant (homogeneity test, = 0.66). There was no effect of age or sex ( > 0.05). To obtain representative national DRCC, data of all volunteers were pooled together and analyzed. The fitted parameters of the radiation-induced DC curve were as follows: = 0.0020 (±0.0002) + 0.0369 (±0.0019) + 0.0689 (±0.0009) . The high significance of the fitted coefficients (-test, < 0.0001), along with the close to 1.0 value of the Poisson-based goodness of fit (χ = 3.51, degrees of freedom = 7, = 0.83), indicated excellent fitting with no trend toward lack of fit. The curve was in the middle range of DRCCs published in other populations. The automated DRCC over and under estimated DCs at low (<1 Gy) and high (>2 Gy) doses, respectively, with a significant lack of goodness of fit ( < 0.0001). In conclusion, we have established the reference DRCC for DCs induced by 320 kVp X-rays. There was no effect of age or sex in this cohort of 10 young adults. Although the calibration curve obtained by the automated (unsupervised) scoring misrepresented dicentric yields at low and high doses, it can potentially be useful for triage mode to segregate between false-positive and near 2-Gy exposures from seriously irradiated individuals who require hospitalization.

摘要

在核与放射事故中,无论辐射暴露是由灾难、疏忽还是蓄意行为引起,公共卫生和应急响应部门都需要评估辐射暴露的程度。在此,我们报告了一项针对双着丝粒染色体(DC)的国家参考剂量-反应校准曲线(DRCC)的建立,这是评估意外暴露中所接受辐射剂量的前提条件。从10名年龄在20 - 40岁(中位数 = 29岁)的志愿者(3名女性和7名男性)身上采集外周血样本。血液样本、细胞遗传学制备及分析均遵循国际原子能机构2011年的EPR - 生物剂量测定报告。使用320 kVp的X射线进行辐照。Metafer系统用于自动并辅助(消除假阳性和纳入真阳性)中期细胞的发现及双着丝粒染色体计分。双着丝粒染色体产率拟合线性 - 二次模型。辅助DRCC的结果显示个体间存在一些差异,但无统计学意义(齐性检验,P = 0.66)。年龄和性别均无影响(P > 0.05)。为获得具有代表性的国家DRCC,将所有志愿者的数据汇总并进行分析。辐射诱导的双着丝粒染色体曲线的拟合参数如下:y = 0.0020(±0.0002)+ 0.0369(±0.0019)x + 0.0689(±0.0009)x²。拟合系数的高度显著性(t检验,P < 0.0001),以及基于泊松的拟合优度接近1.0的值(χ² = 3.51,自由度 = 7,P = 0.83),表明拟合良好,无拟合不足的趋势。该曲线处于其他人群发表的DRCC的中间范围。自动DRCC在低剂量(<1 Gy)和高剂量(>2 Gy)时分别高估和低估了双着丝粒染色体,拟合优度显著不足(P < 0.0001)。总之,我们建立了320 kVp X射线诱导的双着丝粒染色体的参考DRCC。在这10名年轻成年人队列中,年龄和性别均无影响。尽管通过自动(无监督)计分获得的校准曲线在低剂量和高剂量时错误表征了双着丝粒产率,但它可能对分诊模式有用,以区分假阳性和接近2 Gy的暴露与需要住院治疗的严重受照个体。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/b4b3/7793750/d8145dc4d66c/fpubh-08-599194-g0001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验