Suppr超能文献

眼用粘弹剂辅助下亚氟烷内注式反转内界膜瓣治疗黄斑裂孔视网膜脱离手术:一种新方法。

Sub-perfluoro-n-octane injection of ocular viscoelastic device assisted inverted internal limiting membrane flap for macular hole retinal detachment surgery: a novel technique.

机构信息

Department of Ophthalmology, Chang Gung Memorial Hospital, No. 5, Fu-Hsing Street, Taoyuan, 333, Taiwan.

College of Medicine, Chang Gung University, Taoyuan, Taiwan.

出版信息

BMC Ophthalmol. 2020 Mar 21;20(1):116. doi: 10.1186/s12886-020-01393-1.

Abstract

BACKGROUND

To evaluate the feasibility of a surgical technique using a sub-perfluoro-n-octane (PFO) injection of ocular viscoelastic device (OVD) to stabilize inverted internal limiting membrane (ILM) flap for the treatment of macular hole retinal detachment (MHRD).

METHODS

This study was a retrospective, consecutive, interventional case series. Patients who underwent MHRD surgery with sub-PFO injection of OVD to stabilize inverted ILM flap onto the macular hole (MH) were reviewed. The color fundus and optical coherence tomography (OCT) images were collected and evaluated. The best-corrected visual acuity (BCVA) before and after surgery were compared as the functional outcome.

RESULTS

The study included 8 eyes of 8 consecutive patients (mean age: 61.8 ± 7.1 years; mean follow-up period: 9.0 ± 2.5 months). All eyes (100%) achieved successful MH closure; 7 eyes (87.5%) demonstrated complete retinal reattachment, and 1 eye (12.5%) had minimal residual subretinal fluid parafoveally. Of the 8 patients, 7 patients (87.5%) had achieved improvement in BCVA after the primary surgery, whereas 1 eye remained stable. The average BCVA before and after the surgery at the last visit improved from 20/843 (1.63 ± 0.48 logMAR) to 20/200 (1.00 ± 0.39 logMAR) (P = 0.016). Anatomically, near-normal foveal contour was noted in five (62.5%) eyes at the final follow-up.

CONCLUSIONS

The use of sub-PFO injection of OVD in MHRD surgery could stabilize inverted ILM flaps, achieve good anatomical results and improve postoperative BCVA.

摘要

背景

评估在黄斑裂孔视网膜脱离(MHRD)手术中使用过氟戊烷(PFO)下眼内黏弹剂(OVD)注射以稳定倒置内界膜(ILM)瓣的手术技术的可行性。

方法

这是一项回顾性、连续的、干预性病例系列研究。回顾性分析了 8 例(8 只眼)接受 MHRD 手术并使用 PFO 下 OVD 注射以稳定倒置 ILM 瓣贴附于黄斑裂孔(MH)的患者。收集并评估眼底彩色照片和光学相干断层扫描(OCT)图像。比较手术前后最佳矫正视力(BCVA),作为功能结果。

结果

该研究包括 8 例(8 只眼)连续患者(平均年龄:61.8±7.1 岁;平均随访时间:9.0±2.5 个月)。所有眼(100%)均成功闭合 MH;7 只眼(87.5%)完全视网膜复位,1 只眼(12.5%)黄斑旁有少量残余视网膜下积液。8 例患者中,7 例(87.5%)在初次手术后 BCVA 得到改善,1 例保持稳定。末次随访时,手术前后平均 BCVA 从 20/843(1.63±0.48 logMAR)提高到 20/200(1.00±0.39 logMAR)(P=0.016)。在最后一次随访时,5 只眼(62.5%)的黄斑中心凹形态接近正常。

结论

在 MHRD 手术中使用 PFO 下 OVD 注射可以稳定倒置 ILM 瓣,获得良好的解剖学结果,并提高术后 BCVA。