George Keith, Burke Shane, Park Sandra, Suarez Luis, Riesenburger Ron
Department of Neurosurgery, Tufts Medical Center, Boston, MA, USA.
Department of Vascular Surgery, Tufts Medical Center, Boston, MA, USA.
J Surg Case Rep. 2020 Mar 17;2020(3):rjaa040. doi: 10.1093/jscr/rjaa040. eCollection 2020 Mar.
Pedicle screws are commonly used in spinal surgeries and are relatively safe, with venous complications occurring rarely. We report a patient with imaging following a L4-5 fusion that showed indentation of the inferior vena cava and right common iliac vein by the right L4 and L5 pedicle screws. She underwent revision surgery in which the hardware was removed and no bleeding was observed. Intraoperative venogram confirmed vascular integrity and absence of indentation on the venous structures following screw removal. The patient recovered without complications. Venous contact by pedicle screws should be treated on a case-by-case basis in a multidisciplinary approach with vascular surgery. We discuss a treatment algorithm for the operative management of this problem.
椎弓根螺钉常用于脊柱手术,相对安全,静脉并发症很少发生。我们报告了一名患者,其在L4-5融合术后的影像学检查显示,右侧L4和L5椎弓根螺钉压迫下腔静脉和右髂总静脉。她接受了翻修手术,术中取出了内固定装置,未观察到出血情况。术中静脉造影证实血管完整,取出螺钉后静脉结构上无压迫。患者康复,无并发症。对于椎弓根螺钉压迫静脉的情况,应采用多学科方法,根据具体情况进行处理。我们讨论了针对该问题手术管理的治疗方案。