Yu Guanling, Ma Shuiying, Zhu Yueting, Liu Yujin, Zhang Haozhen, Wu Keliang, Hao Aijun
Center for Reproductive Medicine, Shandong University, No. 157, Jingliu Road, Jinan, 250021, Shandong, China.
Department of Histology and Embryology, Shandong University School of Medicine, No. 44, Wenhua Xi Road, Jinan, 250012, Shandong, China.
Cytotechnology. 2020 Apr;72(2):217-226. doi: 10.1007/s10616-020-00371-1. Epub 2020 Mar 31.
To modify a fixation method improving the intensity and clarity of the single blastomeric signal detection by fluorescence in situ hybridization (FISH) in preimplantation genetic diagnosis. 333 cycles of assisted reproduction with preimplantation genetic diagnosis FISH (PGD-FISH) performed in our hospital were analyzed and a total of 3452 single blastomeres were obtained. For the conventional fixation method, the blastomeres were kept in 0.1% sodium citrate with 0.2 mg/ml bovine serum albumin (BSA) for 2-5 min. FISH was performed and the internal relationship between embryo quality and fixed rate, signal detection rate, and signal determination rate was explored. With the modified method, 91.54% of blastomeres were fixed, while 88.30% were fixed with the conventional method. The signal detection rate was significantly increased for the modified group than for the conventional group (compared 98.53% with 94.78%, P < 0.001). Especially, the signal determination rate also showed a significant difference between the two methods (compared 90.51% with 74.17%, P < 0.001). After the development of the fixation method, the fixation efficiency and the signal determination rate were greatly improved, providing more definite diagnosis for the patient. It will hopefully allow more assisted reproduction programs to offer their patients preimplantation genetic diagnosis with FISH.
为改进一种固定方法,以提高植入前基因诊断中荧光原位杂交(FISH)对单个卵裂球信号检测的强度和清晰度。分析了我院进行的333个植入前基因诊断FISH(PGD-FISH)辅助生殖周期,共获得3452个单个卵裂球。对于传统固定方法,将卵裂球置于含0.2mg/ml牛血清白蛋白(BSA)的0.1%柠檬酸钠中2-5分钟。进行FISH,并探讨胚胎质量与固定率、信号检测率和信号确定率之间的内在关系。采用改良方法,91.54%的卵裂球被固定,而传统方法为88.30%。改良组的信号检测率显著高于传统组(分别为98.53%和94.78%,P < 0.001)。特别是,两种方法的信号确定率也存在显著差异(分别为90.51%和74.17%,P < 0.001)。固定方法改进后,固定效率和信号确定率大大提高,为患者提供了更明确的诊断。有望使更多辅助生殖项目为患者提供FISH植入前基因诊断。