Influence of a customized three-dimensionally printed drill guide on the accuracy of pedicle screw placement in lumbosacral vertebrae: An ex vivo study.

作者信息

Beer Patricia, Park Brian H, Steffen Frank, Smolders Decvn Lucas A, Pozzi Antonio, Knell Sebastian C

机构信息

Clinic for Small Animal Surgery, Vetsuisse Faculty University of Zurich, Zurich, Switzerland.

出版信息

Vet Surg. 2020 Jul;49(5):977-988. doi: 10.1111/vsu.13417. Epub 2020 Apr 7.

Abstract

OBJECTIVE

To compare the accuracy of pedicle screw insertion (PSI) into canine lumbosacral vertebrae with custom-made three-dimensionally (3D)-printed drill guides or freehand insertion.

STUDY DESIGN

Ex vivo study.

SAMPLE POPULATION

Nineteen canine lumbosacral specimens.

METHODS

Drill guides for PSI were designed on the basis of safe screw insertion trajectories by using preoperative computed tomography (CT) and produced by 3D printing of templates. Right and left sides of the specimens were randomly allocated to two groups; 4-mm pedicle screws were inserted in L5-L6 and L7-S1 spinal segments either freehand (control group) or with custom-made drill guides (guide group). Sixty-six screws were inserted with each method. Insertion angles (α, β), bone stock, and vertebral canal breach were assessed according to postoperative CT. χ Tests were used to compare vertebral canal breach between groups and vertebrae.

RESULTS

Breaches in the vertebral canal were less common (P < .001) when screws were placed with a guide in the guide group (9/66, 14%) than without a guide (30/66, 45%). The rate of vertebral canal breach differed at L5 (P = .021) but not at L6 (P = .05), L7 (P = .075) or S1 (P = .658). The angle of insertion (α) did not differ between specimens with and without breaches (guide, P = .068; control, P = .394).

CONCLUSION

The use of a customized 3D-printed guide generally improved the accuracy of PSI in canine lumbosacral vertebrae, although statistical significance was reached only at L5.

CLINICAL SIGNIFICANCE

The use of customized drill guides may be considered as an alternative to freehand PSI in the lumbosacral area, especially for L5-L6 vertebrae.

摘要

目的

比较使用定制的三维(3D)打印钻孔导向器或徒手将椎弓根螺钉植入犬腰骶椎的准确性。

研究设计

体外研究。

样本群体

19个犬腰骶标本。

方法

基于术前计算机断层扫描(CT)确定的安全螺钉植入轨迹设计椎弓根螺钉植入的钻孔导向器,并通过模板的3D打印制作。标本的左右两侧随机分为两组;在L5-L6和L7-S1脊柱节段徒手(对照组)或使用定制钻孔导向器(导向组)植入4毫米椎弓根螺钉。每种方法植入66枚螺钉。根据术后CT评估植入角度(α、β)、骨量和椎管破裂情况。采用χ检验比较组间和椎体间的椎管破裂情况。

结果

在导向组中,使用导向器植入螺钉时椎管破裂的情况较少见(P < .001)(9/66,14%),而不使用导向器时(30/66,45%)。L5处的椎管破裂率存在差异(P = .021),但L6(P = .05)、L7(P = .075)或S1(P = .658)处无差异。有破裂和无破裂的标本之间的植入角度(α)无差异(导向组,P = .068;对照组,P = .394)。

结论

使用定制的3D打印导向器总体上提高了犬腰骶椎椎弓根螺钉植入的准确性,尽管仅在L5处达到统计学意义。

临床意义

在腰骶部区域,尤其是L5-L6椎体,可考虑使用定制钻孔导向器替代徒手椎弓根螺钉植入。