Abstract

PURPOSE

To study the repeatability of anterior surface and Bowman's layer curvature in normal and keratoconic eyes using optical coherence tomography (OCT).

METHODS

In this study, 96 normal and 96 keratoconic eyes underwent corneal imaging using Pentacam (Oculus Optikgeräte, Wetzlar, Germany) and OCT (Triton, Topcon Corporation, Tokyo, Japan). The elevation data from segmented air-epithelium (A-E) and epithelium-Bowman's layer (E-B) interfaces in OCT scans were used to quantify curvature and aberrations. The wavefront aberrations were evaluated with the ray tracing method and 6th order Zernike polynomials. The intraclass correlation coefficient (ICC), within-subject standard deviation (Sw), and coefficient of variation (CoV) were used to assess repeatability.

RESULTS

For curvatures, the Sw was less than 0.25 diopters (D) for the normal and keratoconic eyes. The Sw was highest for root mean square of lower order aberrations (0.14 µm) in keratoconic eyes. The CoV for curvatures was well below 0.5% for both groups. For some aberrations irrespective of groups, the CoV was greater because some individual aberrations (mean of three successive measurements) tended to be smaller in magnitude and even a small Sw resulted in a high CoV. For all variables, the ICC ranged between 0.80 and 0.99 for both the OCT and Pentacam measurements. Most variables were similar between the A-E and E-B interfaces (P > .05) for both groups. However, both differed significantly from all Pentacam variables (P < .05) in normal and keratoconic eyes.

CONCLUSIONS

The repeatability of OCT curvatures and aberrations compared well with the Pentacam indices for normal and keratoconic eyes. [J Refract Surg. 2020;36(4):247-252.].

摘要

目的

使用光学相干断层扫描(OCT)研究正常眼和圆锥角膜眼中前表面和 Bowman 层曲率的可重复性。

方法

本研究中,96 只正常眼和 96 只圆锥角膜眼使用 Pentacam(德国 Oculus Optikgeräte 公司)和 OCT(日本 Topcon 公司 Triton)进行角膜成像。OCT 扫描中分段的空气上皮(A-E)和上皮-Bowman 层(E-B)界面的高程数据用于量化曲率和像差。使用光线追踪法和 6 阶 Zernike 多项式评估波前像差。使用组内相关系数(ICC)、个体内标准差(Sw)和变异系数(CoV)评估重复性。

结果

对于曲率,正常眼和圆锥角膜眼的 Sw 小于 0.25 屈光度(D)。圆锥角膜眼的均方根低阶像差 Sw 最高(0.14 µm)。两组的曲率 CoV 均低于 0.5%。对于一些像差,无论分组如何,CoV 都较大,因为一些个体像差(三次连续测量的平均值)的幅度较小,即使 Sw 较小,也会导致较高的 CoV。对于所有变量,OCT 和 Pentacam 测量的 ICC 均在 0.80 到 0.99 之间。两组的 A-E 和 E-B 界面的大多数变量相似(P >.05)。然而,两组与所有 Pentacam 变量均有显著差异(P <.05),无论是在正常眼还是圆锥角膜眼中。

结论

与正常眼和圆锥角膜眼的 Pentacam 指数相比,OCT 曲率和像差的重复性较好。[J Refract Surg. 2020;36(4):247-252.]。