Zarabian Tara, Azadi Mood Saba, Kiomarsi Nazanin, Noorollahian Homa, Hakimiha Neda
Department of Pediatric Dentistry, Dental Faculty, Tehran University of Medical Sciences, International Campus, Tehran, Iran.
Dentist, Tehran University of Medical Sciences, Tehran, Iran.
J Lasers Med Sci. 2020 Spring;11(2):181-186. doi: 10.34172/jlms.2020.30. Epub 2020 Mar 15.
Advances have been made in the composition of flowable composites in recent years and self-adhering composites, which do not require a bonding agent, have recently been introduced to the market. This study aimed to assess the microshear bond strength (µSBS) of a self-adhering flowable composite (Vertise) to primary enamel treated with a graphite disc with silicon carbide particles (SIC) and laser irradiation, the result of which was compared to that of a conventional flowable composite (Premise). In this in vitro, experimental study, 72 samples of sound primary enamel were evaluated. A smooth enamel surface was obtained using a graphite disc. Next, the erbium chromium yttrium scandium gallium garnet (Er,Cr:YSGG) laser was used for enamel surface treatment in half of the samples (n=36). All the samples were then randomly divided into 4 groups of (i) Premise flowable composite (PF) without laser (n=18), (ii) Vertise flowable composite (VF) without laser (n=18), (iii) PF with laser (n=18), and (iv) VF with laser (n=18). The teeth were then incubated at 37°C for 24 hours and were then subjected to thermocycling. The µSBS of samples was measured using a universal testing machine and reported in megapascal (MPa). Data were analyzed using SPSS via the two-way ANOVA and independent-samples t test at <0.05. The mean µSBS of VF was significantly higher to the laser-treated samples (13.60±5.47) compared with the non-treated samples (5.89±2.42) (<0.001). However, no significant difference was noted in the µSBS of PF to the laser-treated (13.18±3.45) and non-treated samples (16.06±3.52) (=0.058). The µSBS of the conventional flowable composite is higher than that of the self-adhering flowable composite to the enamel of primary teeth. Enamel surface treatment with laser irradiation increases the µSBS of self-adhering flowable composites.
近年来,可流动复合树脂的成分有了进展,最近市场上推出了无需粘结剂的自粘结复合树脂。本研究旨在评估一种自粘结可流动复合树脂(Vertise)与经碳化硅(SIC)颗粒石墨盘处理及激光照射的乳牙釉质之间的微剪切粘结强度(µSBS),并将结果与传统可流动复合树脂(Premise)进行比较。在这项体外实验研究中,对72个健康乳牙釉质样本进行了评估。使用石墨盘获得光滑的釉质表面。接下来,在一半的样本(n = 36)中使用铒铬钇钪镓石榴石(Er,Cr:YSGG)激光进行釉质表面处理。然后将所有样本随机分为4组:(i)未用激光处理的Premise可流动复合树脂(PF)组(n = 18),(ii)未用激光处理的Vertise可流动复合树脂(VF)组(n = 18),(iii)用激光处理的PF组(n = 18),以及(iv)用激光处理的VF组(n = 18)。然后将牙齿在37°C下孵育24小时,接着进行热循环处理。使用万能试验机测量样本的µSBS,并以兆帕(MPa)为单位报告。通过SPSS软件,采用双向方差分析和独立样本t检验对数据进行分析,检验水准为<0.05。与未处理的样本(5.89±2.42)相比,VF对激光处理样本的平均µSBS显著更高(13.60±5.47)(<0.001)。然而,PF对激光处理样本(13.18±3.45)和未处理样本(16.06±3.52)的µSBS未观察到显著差异(P = 0.058)。对于乳牙釉质,传统可流动复合树脂的µSBS高于自粘结可流动复合树脂。激光照射釉质表面可提高自粘结可流动复合树脂的µSBS。