Department of Ophthalmology, Ulucanlar Eye Training and Research Hospital, Ankara, Turkey.
Department of Ophthalmology, Special Kayseri Maya Eye Hospital, Kayseri, Turkey; and.
Cornea. 2020 Sep;39(9):1080-1085. doi: 10.1097/ICO.0000000000002339.
To compare the central corneal thickness (CCT) measurements measured by using the Pentacam Scheimpflug system with the CCT measured using ultrasound pachymetry (UP) and to compare the compatibility between the methods in normal, keratoconic, and cross-linked keratoconic corneas.
The study included 50 eyes of 50 patients with keratoconus (keratoconus group), 50 eyes of 50 patients with progressive keratoconus who underwent corneal cross-linking treatment (CCL group), and 50 eyes of 50 healthy subjects (control group). Patients in the keratoconus and CCL groups were further classified into mild (mean keratometry [Km] ≤ 47 D) and moderate keratoconus subgroups (47.0 < Km < 52.0 D). CCT values were noted from the Pentacam Scheimpflug and UP.
The difference between the Pentacam and UP values was largest in the CCL group (-20.9 0.21.5 μm), followed by the keratoconus and control groups (-10.6 0.20.3 and 0.4 0.6.8 μm). The Pentacam and UP measurements were not comparable in the keratoconus and CCL groups (P = 0.001 and P < 0.001), whereas they were comparable in the control group (P = 0.62). In subgroup analysis, the 2 methods were comparable in the mild keratoconus subgroup (P = 0.12) and not comparable in the moderate keratoconus subgroup and in both mild and moderate subgroups of the CCL group (P = 0.001, P < 0.001 and P < 0.001).
Pentacam Scheimpflug tomography and UP can be used interchangeably in normal and mild keratoconic eyes, but not in moderate keratoconic and cross-linked keratoconic eyes. Pachymetry measurements from Scheimpflug must be interpreted with extreme caution with different methods before planning an invasive procedure in these eyes.
比较 Pentacam 眼前节断层扫描仪测量的中央角膜厚度(CCT)与超声角膜测厚仪(UP)测量的 CCT,并比较正常、圆锥角膜和交联圆锥角膜中两种方法的兼容性。
该研究纳入了 50 例圆锥角膜患者(圆锥角膜组)的 50 只眼、50 例行角膜交联治疗的进展性圆锥角膜患者(交联组)的 50 只眼和 50 例健康受试者(对照组)的 50 只眼。圆锥角膜组和交联组患者进一步分为轻度(平均角膜曲率[Km]≤47D)和中度圆锥角膜亚组(47.0<Dm<52.0D)。从 Pentacam 眼前节断层扫描仪和 UP 记录 CCT 值。
交联组的 Pentacam 和 UP 值之间的差异最大(-20.9μm±0.21.5μm),其次是圆锥角膜组和对照组(-10.6μm±0.20.3μm和 0.4μm±0.6μm)。在圆锥角膜组和交联组中,Pentacam 和 UP 测量值不可比(P=0.001 和 P<0.001),而在对照组中是可比的(P=0.62)。在亚组分析中,两种方法在轻度圆锥角膜亚组中是可比的(P=0.12),在中度圆锥角膜亚组和交联组的轻度和中度亚组中均不可比(P=0.001、P<0.001 和 P<0.001)。
Pentacam 眼前节断层扫描仪和 UP 可在正常和轻度圆锥角膜眼中互换使用,但在中度圆锥角膜和交联圆锥角膜眼中不可互换使用。在这些眼中计划侵入性手术之前,必须非常谨慎地解释不同方法的 Scheimpflug 角膜测厚术测量值。