Suppr超能文献

使用眼前节光学相干断层扫描(AS-OCT)和 Pentacam HR 地形图比较正常眼和圆锥角膜眼中的角膜测量值。

Comparison of corneal measurements in normal and keratoconus eyes using Anterior Segment Optical Coherence Tomography (AS-OCT) and Pentacam HR topographer.

机构信息

Department of Ophthalmology, Faculty of Medicine, Fayoum University, Fayoum, Egypt.

出版信息

BMC Ophthalmol. 2023 May 3;23(1):194. doi: 10.1186/s12886-023-02946-w.

Abstract

BACKGROUND

Keratoconus (KC) is easily recognized by its unique topographic pattern, but it can be difficult to distinguish subclinical form of the disease from the normal cornea. Optovue anterior segment optical coherence tomography (AS-OCT) helps diagnose KC.

AIM OF THE WORK

To assess and the level of agreement of Keratometry-readings (K), Central Corneal Thickness (CCT) and Thinnest Corneal Thickness (TCT) measurements obtained by Optovue AS-OCT and Wavelight Oculyzer Pentacam HR in two groups: KC eyes and normal eyes.

PATIENTS AND METHODS

This is a prospective clinical observational study. The study included 110 eyes divided into two groups. The study group included 62 eyes with topographic evidence of KC. The control group included 48 eyes of normal subjects with no topographic evidence of KC. All of the participants underwent full cycloplegic refraction, spectacle best-corrected distance visual acuity, comprehensive slit-lamp biomicroscopy and fundoscopy. All participants underwent corneal topography by Pentacam HR and AS-OCT.

RESULTS

There were highly significant differences between the studied groups as regarding BCVA, intraocular pressure and CCT measurements which were found to be lower among KC group compared to the control one. There were highly significant differences between the studied groups regarding TCT measurement detected by Pentacam HR and AS-OCT which was found to be lower among the keratoconus group compared to the control one (470.9, 455.7 versus 541.9 and 518.7 respectively).

CONCLUSION

Both Scheimpflug-based imaging and AS-OCT provide comparable readings with a good agreement regarding corneal pachymetry in keratoconus group with accurate identification of KC eyes and healthy ones. However, there was a significant difference in K readings between both devices in Keratoconus and control group.

摘要

背景

圆锥角膜(KC)的独特地形模式很容易识别,但要将疾病的亚临床形式与正常角膜区分开来可能具有挑战性。Optovue 眼前节光学相干断层扫描(AS-OCT)有助于诊断 KC。

目的

评估并比较 Optovue AS-OCT 和 Wavelight Oculyzer Pentacam HR 在两组中的角膜曲率读数(K)、中央角膜厚度(CCT)和最薄角膜厚度(TCT)测量值的一致性,这两组分别为 KC 眼和正常眼。

患者和方法

这是一项前瞻性临床观察研究。该研究包括 110 只眼,分为两组。研究组包括 62 只具有 KC 地形证据的眼。对照组包括 48 只无 KC 地形证据的正常眼。所有参与者均接受充分的睫状肌麻痹屈光检查、矫正视力、综合裂隙灯生物显微镜和眼底检查。所有参与者均接受 Pentacam HR 和 AS-OCT 角膜地形图检查。

结果

在 BCVA、眼压和 CCT 测量方面,研究组之间存在显著差异,KC 组的这些值明显低于对照组。在 Pentacam HR 和 AS-OCT 检测的 TCT 测量方面,两组之间存在显著差异,KC 组的 TCT 明显低于对照组(分别为 470.9、455.7 与 541.9 和 518.7)。

结论

Scheimpflug 成像和 AS-OCT 都能提供类似的角膜厚度读数,并且在 KC 组中具有良好的一致性,能够准确识别 KC 眼和正常眼。然而,在 KC 组和对照组中,两种设备的 K 读数存在显著差异。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1e84/10155327/55aa3f30c499/12886_2023_2946_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验