Pabon J P, Plomp R
Free University Hospital, Amsterdam.
J Speech Hear Res. 1988 Dec;31(4):710-22. doi: 10.1044/jshr.3104.710.
A new method for automatic voice-quality registration is presented. The method is based on a technique called phonetography, which is the registration of the dynamic range of a voice as a function of fundamental frequency. In the new phonetogram-recording method fundamental frequency (Fo) and sound-pressure level (SPL) are automatically measured and represented in an XY-diagram. Three additional acoustical voice-quality parameters are measured simultaneously with Fo and SPL: (a) jitter in the Fo as a measure for roughness, (b) the SPL difference between the 0-1.5 kHz and the 1.5-5 kHz bands as a measure for sharpness, and (c) the vocal-noise level above 5 kHz as a measure for breathiness. With this method, the voice-quality parameter values, which may change substantially as a function of Fo and SPL, are pinned to a reference position in the patient's total vocal range. Seen as a reference tool, the phonetogram opens the possibility for a more meaningful comparison of voice-quality data. Some examples, demonstrating the dependence of the chosen quality parameters on Fo and SPL are given.
提出了一种自动语音质量记录的新方法。该方法基于一种称为声谱记录法的技术,即根据基频记录语音的动态范围。在新的声谱记录方法中,基频(Fo)和声压级(SPL)会自动测量,并以XY图表示。另外三个声学语音质量参数与Fo和SPL同时测量:(a)Fo中的抖动作为粗糙度的度量;(b)0-1.5kHz和1.5-5kHz频段之间的SPL差异作为尖锐度的度量;(c)5kHz以上的嗓音噪声水平作为呼吸声的度量。通过这种方法,可能随Fo和SPL大幅变化的语音质量参数值被固定在患者整个发声范围内的一个参考位置。作为一种参考工具,声谱图为更有意义地比较语音质量数据提供了可能性。给出了一些示例,展示了所选质量参数对Fo和SPL的依赖性。