The precision of soft metal processing technologies is poorly documented. This study compared marginal and internal fit of presintered cobalt-chromium (Co-Cr) and zirconia three-unit fixed dental prostheses (FDPs) to cast Co-Cr.
Three-unit FDPs were prepared on metal dies (N = 60) from typodont preparations of the maxillary right first premolar and molar. A standardized preparation of a metal-ceramic restoration was done on abutment teeth. The dies (N = 60) were scanned and divided into three groups (n = 20/group) to receive the FDP made of presintered Co-Cr (Ceramill Si), presintered zirconia (Ceramill Zi), and cast Co-Cr (Girobond NB). Each framework was seated on its specific cast. A replica technique was used for marginal and internal discrepancies measurements in mesiodistal and buccolingual planes. Data were analyzed using the Levene test, t-test, and analysis of variance (α = 0.05).
When the overall mean discrepancy values were compared in the mesiodistal plane, a significant difference was found between Ceramill Sintron and Ceramill Zi groups (p = 0.026). No significant difference was detected between Girobond NB and Ceramill Sintron groups and between Girobond NB and Ceramill Zi groups (p = 0.537 and p = 0.569, respectively). In the buccolingual plane, there was no significant difference in the overall mean discrepancy between the three groups: CS/CZ (p = 1.000), GI/CS (p = 0.51), and GI/CZ (p = 0.87). Significant differences at several measurement points were found at the inter or intramaterial level. The increase in discrepancy values between marginal and occlusal measurements was evident for the three groups.
Presintered three-unit FDPs fabricated from zirconia and Co-Cr exhibited internal and marginal discrepancy values similar to cast Co-Cr. A significant difference was reported between CS and CZ in mesiodistal planes. The axial and marginal differences in values for the three tested groups were below or around the 120 µm clinically acceptable threshold except for the occlusal area. When comparing first premolar to first molar, the internal and marginal discrepancies were similar with no apparent distortion of the framework after the sintering process.
软金属加工技术的精度记录不佳。本研究比较了预烧结钴铬(Co-Cr)和氧化锆三单位固定义齿(FDP)与铸造 Co-Cr 的边缘和内部适合性。
从上颌右侧第一前磨牙和磨牙的典型预备体上在金属模具(N = 60)上制备三单位 FDP。在基牙上进行金属陶瓷修复的标准化制备。将模具(N = 60)扫描并分为三组(每组 20 个,n = 20/组),以接收由预烧结 Co-Cr(Ceramill Si)、预烧结氧化锆(Ceramill Zi)和铸造 Co-Cr(Girobond NB)制成的 FDP。每个框架都安装在其特定的铸造物上。复制技术用于测量近远中面和颊舌面的边缘和内部差异。使用 Levene 检验、t 检验和方差分析(α = 0.05)分析数据。
当在近远中面比较整体平均差异值时,发现 Ceramill Sintron 和 Ceramill Zi 组之间存在显著差异(p = 0.026)。Girobond NB 和 Ceramill Sintron 组之间以及 Girobond NB 和 Ceramill Zi 组之间未检测到显著差异(p = 0.537 和 p = 0.569)。在颊舌面,三组之间的整体平均差异无显著差异:CS/CZ(p = 1.000)、GI/CS(p = 0.51)和 GI/CZ(p = 0.87)。在不同材料水平上,在几个测量点发现了显著差异。三个组的边缘和咬合测量之间的差异值增加明显。
由氧化锆和 Co-Cr 制成的预烧结三单位 FDP 表现出与铸造 Co-Cr 相似的内部和边缘差异值。在近远中面报告了 CS 和 CZ 之间的显著差异。三个测试组的轴向和边缘值差异在 120 µm 临床可接受阈值以下或接近该阈值,除了咬合区域。当比较第一前磨牙和第一磨牙时,烧结后框架没有明显变形,内部和边缘差异相似。