新一代鼓膜体温计在不同截断值下用于儿童的诊断准确性:系统评价和荟萃分析。

Diagnostic test accuracy of new generation tympanic thermometry in children under different cutoffs: a systematic review and meta-analysis.

机构信息

Nursing Department, Hospital Affiliated 5 to Nantong University (Taizhou People's Hospital), 366 Taihu Road, Medical High-tech district, Taizhou, Jiangsu Province, China.

出版信息

BMC Pediatr. 2020 May 12;20(1):210. doi: 10.1186/s12887-020-02097-7.

Abstract

BACKGROUND

The infrared tympanic thermometer (IRTT) is a popular method for temperature screening in children, but it has been debated for the low accuracy and reproducibility compared with other measurements. This study was aimed to identify and quantify studies reporting the diagnostic accuracy of the new generation IRTT in children and to compare the sensitivity and specificity of IRTT under different cutoffs and give the optimal cutoff.

METHODS

Articles were derived from a systematic search in PubMed, Web of Science Core Collection, and Embase, and were assessed for internal validity by the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). The figure of risk of bias was created by Review Manager 5.3 and data were synthesized by MetaDisc 1.4.

RESULTS

Twelve diagnostic studies, involving 4639 pediatric patients, were included. The cut-offs varied from 37.0 °C to 38.0 °C among these studies. The cut-off 37.8 °C was with the highest sROC AUC (0.97) and Youden Index (0.83) and was deemed to be the optimal cutoff.

CONCLUSION

The optimal cutoff for infrared tympanic thermometers is 37.8 °C. New Generation Tympanic Thermometry is with high diagnostic accuracy in pediatric patients and can be an alternative for fever screening in children.

摘要

背景

红外鼓膜温度计(IRTT)是一种常用于儿童体温筛查的方法,但与其他测量方法相比,其准确性和可重复性较低,因此一直存在争议。本研究旨在确定和量化报告新一代 IRTT 在儿童中的诊断准确性的研究,并比较不同截断值下的 IRTT 的敏感性和特异性,并给出最佳截断值。

方法

文章源自于在 PubMed、Web of Science Core Collection 和 Embase 中进行的系统搜索,并通过诊断准确性研究的质量评估-2(QUADAS-2)进行了内部有效性评估。风险偏倚图由 Review Manager 5.3 创建,数据通过 MetaDisc 1.4 进行综合。

结果

纳入了 12 项诊断研究,涉及 4639 名儿科患者。这些研究中的截断值从 37.0°C 到 38.0°C 不等。截断值为 37.8°C 时的 sROC AUC(0.97)和 Youden 指数(0.83)最高,被认为是最佳截断值。

结论

红外鼓膜温度计的最佳截断值为 37.8°C。新一代鼓膜温度计在儿科患者中具有较高的诊断准确性,可作为儿童发热筛查的替代方法。