Chua Su-Kiat, Chen Lung-Ching, Lien Li-Ming, Lo Huey-Ming, Liao Zhen-Yu, Chao Shu-Ping, Chuang Cheng-Yen, Chiu Chiung-Zuan
School of Medicine, Fu Jen Catholic University, New Taipei City.
Division of Cardiology, Department of Internal Medicine, Shin Kong Wu Ho-Su Memorial Hospital.
Acta Cardiol Sin. 2020 May;36(3):251-259. doi: 10.6515/ACS.202005_36(3).20190903A.
Although 24-hour Holter monitoring is routinely used for patients with suspected paroxysmal arrhythmia, its sensitivity in detecting such arrhythmias is insufficient.
We compared a 14-day electrocardiography (ECG) monitor patch - a single-use, noninvasive, waterproof, continuous monitoring patch - with a 24-hour Holter monitor in 32 consecutive patients with suspected arrhythmia.
The 14-day ECG patch was well tolerated, and its rates of detection of relevant arrhythmias on days 1, 3, 7, and 14 were 13%, 28%, 47%, and 66%, respectively. The detection rate of paroxysmal arrhythmias was significantly higher for the 14-day ECG patch than for the 24-hour Holter monitor (66% vs. 9%, p < 0.001). Among the 32 patients, 202 atrial fibrillation or atrial flutter episodes were detected in 6 patients (22%) with the 14-day ECG patch; however, only 1 atrial fibrillation episode was detected in a patient (3%, p < 0.05) with the 24-hour Holter monitor. Other clinically relevant arrhythmias recorded on the 14-day ECG patch included 21 (65.5%) episodes of supraventricular tachycardia, 2 (6.3%) long pause, and 2 (6.3%) ventricular arrhythmias. The mean dermal response score immediately after removal of the 14-day ECG patch from the patients was 0.64, which indicated minimal erythema.
The 14-day ECG patch was well tolerated and allowed for longer continuous monitoring than the 24-hour Holter monitor, thus resulting in improved clinical accuracy in the detection of paroxysmal arrhythmias. Future studies should examine the long-term effectiveness of 14-day ECG patches for managing selected patients.
尽管24小时动态心电图监测常用于疑似阵发性心律失常的患者,但其检测此类心律失常的敏感性不足。
我们将一种14天心电图(ECG)监测贴片——一种一次性使用、无创、防水的连续监测贴片——与24小时动态心电图监测仪在32例连续的疑似心律失常患者中进行了比较。
14天心电图贴片耐受性良好,其在第1、3、7和14天检测相关心律失常的比率分别为13%、28%、47%和66%。14天心电图贴片对阵发性心律失常的检测率显著高于24小时动态心电图监测仪(66%对9%,p<0.001)。在32例患者中,使用14天心电图贴片在6例患者(22%)中检测到202次心房颤动或心房扑动发作;然而,使用24小时动态心电图监测仪仅在1例患者(3%,p<0.05)中检测到1次心房颤动发作。14天心电图贴片记录的其他临床相关心律失常包括21次(65.5%)室上性心动过速发作、2次(6.3%)长间歇和2次(6.3%)室性心律失常。从患者身上取下14天心电图贴片后立即的平均皮肤反应评分为0.64,表明仅有轻微红斑。
14天心电图贴片耐受性良好,与24小时动态心电图监测仪相比可进行更长时间的连续监测,从而提高了阵发性心律失常检测的临床准确性。未来的研究应检验14天心电图贴片对特定患者管理的长期有效性。