Schowalter Sean, Altawil Zaid, Schechter-Perkins Elissa M, Pare Joseph R
Beth Israel Deaconess Medical Center, Department of Internal Medicine, Boston, Massachusetts.
Boston Medical Center, Department of Emergency Medicine, Boston, Massachusetts.
Clin Pract Cases Emerg Med. 2020 Feb 24;4(2):158-160. doi: 10.5811/cpcem.2019.12.45103. eCollection 2020 May.
Bladder scanners allow for quick determination of bladder volumes (BV) with minimal training. BV measured by a machine is generally accurate; however, circumstances exist in which falsely elevated BVs are reported. This case details a patient with a significant small bowel obstruction (SBO) due to superior mesenteric artery syndrome causing a falsely elevated BV. We believe this is the first case report of a SBO causing an elevated BV by bladder scanner. Emergency physicians should be aware of the pitfalls of using bladder scanners, and use their point-of-care ultrasound skills when possible to expand their differential.
膀胱扫描仪只需极少的培训就能快速测定膀胱容量(BV)。机器测量的BV通常是准确的;然而,存在报告的BV值错误升高的情况。本病例详细介绍了一名因肠系膜上动脉综合征导致严重小肠梗阻(SBO)而出现BV值错误升高的患者。我们认为这是首例关于SBO导致膀胱扫描仪测得的BV升高的病例报告。急诊医生应意识到使用膀胱扫描仪存在的陷阱,并尽可能运用其床旁超声技能来拓宽鉴别诊断范围。