Departments of Medical Microbiology.
Gastroenterology.
Eur J Gastroenterol Hepatol. 2020 Aug;32(8):971-975. doi: 10.1097/MEG.0000000000001765.
Prompt and accurate diagnosis of gastrointestinal tuberculosis (GITB) is highly challenging. Current conventional techniques lack sensitivity and are time-consuming. Multi targeted loop-mediated isothermal amplification (LAMP) using two targets (IS6110 and MPB64) is a promising technique for rapid diagnosis of TB.
LAMP test using IS6110 and MPB64 targets for M. tuberculosis complex was performed on ileocecal biopsy samples of 35 clinically suspected patients of GITB and 30 ileocecal biopsy samples of non-tuberculosis control subjects. Results of IS6110 LAMP and MPB64 LAMP were compared with IS6110 PCR and culture INFERENCE: Overall LAMP test (using any of the two targets) had a sensitivity and specificity of 100 and 100%, respectively, for confirmed GITB (five culture positive) cases and 85.71 and 100%, respectively, for clinically suspected 30 ileocecal biopsy samples of GITB. Sensitivity of IS6110 LAMP, MPB64 LAMP and IS6110 PCR for clinically suspected cases was 22 (73.33%), 24 (80%) and 21 (70%), respectively. In total 35 GITB patients, the overall sensitivity of microscopy, culture, IS6110 PCR, IS6110 LAMP, MPB64 LAMP and the multi-targeted LAMP assay (if any of the two targets were used) were 5.71, 14.28, 68.57, 74.28, 82.85 and 85.71%, respectively. Specificity of all the tests was 100%. There were three cases which were missed by IS6110 LAMP and two cases by MPB64 LAMP.
Multi-targeted LAMP is a promising technique for rapid and accurate diagnosis of GITB.
快速准确诊断胃肠道结核 (GITB) 极具挑战性。目前的常规技术缺乏敏感性且耗时。使用两个靶标 (IS6110 和 MPB64) 的多靶向环介导等温扩增 (LAMP) 是一种快速诊断结核的有前途的技术。
对 35 例临床疑似 GITB 患者和 30 例非结核病对照患者的回盲部活检样本进行针对结核分枝杆菌复合群的 IS6110 和 MPB64 靶标的 LAMP 检测。比较 IS6110 LAMP 和 MPB64 LAMP 的结果与 IS6110 PCR 和培养。
多靶标 LAMP 是一种快速准确诊断 GITB 的有前途的技术。