Abstract

AIM/OBJECTIVES/BACKGROUND: The American College of Radiology (ACR) and the American Society for Radiation Oncology (ASTRO) have jointly developed the following practice parameter for image-guided radiation therapy (IGRT). IGRT is radiation therapy that employs imaging to maximize accuracy and precision throughout the entire process of treatment delivery with the goal of optimizing accuracy and reliability of radiation therapy to the target, while minimizing dose to normal tissues.

METHODS

The ACR-ASTRO Practice Parameter for IGRT was revised according to the process described on the ACR website ("The Process for Developing ACR Practice Parameters and Technical Standards," www.acr.org/ClinicalResources/Practice-Parametersand-Technical-Standards) by the Committee on Practice Parameters of the ACR Commission on Radiation Oncology in collaboration with the ASTRO. Both societies then reviewed and approved the document.

RESULTS

This practice parameter is developed to serve as a tool in the appropriate application of IGRT in the care of patients with conditions where radiation therapy is indicated. It addresses clinical implementation of IGRT including personnel qualifications, quality assurance standards, indications, and suggested documentation.

CONCLUSIONS

This practice parameter is a tool to guide clinical use of IGRT and does not make recommendations on site-specific IGRT directives. It focuses on the best practices and principles to consider when using IGRT effectively, especially with the significant increase in imaging data that is now available with IGRT. The clinical benefit and medical necessity of the imaging modality and frequency of IGRT should be assessed for each patient.

摘要

目的/目标/背景:美国放射学院(ACR)和美国放射肿瘤学会(ASTRO)联合制定了以下影像引导放射治疗(IGRT)实践参数。IGRT 是一种利用影像学技术在治疗过程中最大限度地提高准确性和精度的放射治疗方法,旨在优化放射治疗对靶区的准确性和可靠性,同时最大限度地减少对正常组织的剂量。

方法

ACR-ASTRO IGRT 实践参数根据 ACR 网站上描述的流程(“制定 ACR 实践参数和技术标准的流程”,www.acr.org/ClinicalResources/Practice-Parametersand-Technical-Standards)进行修订,由 ACR 放射肿瘤学委员会实践参数委员会与 ASTRO 合作完成。然后,两个协会都对该文件进行了审查和批准。

结果

本实践参数旨在作为在有放射治疗指征的患者护理中适当应用 IGRT 的工具。它涉及 IGRT 的临床实施,包括人员资格、质量保证标准、适应证和建议的文件记录。

结论

本实践参数是指导 IGRT 临床应用的工具,并未对特定部位的 IGRT 指令提出建议。它侧重于有效使用 IGRT 时应考虑的最佳实践和原则,尤其是考虑到现在 IGRT 可提供大量成像数据。应评估每位患者的成像方式和 IGRT 频率的临床获益和医学必要性。