Suppr超能文献

肺部超声检查结果在支气管肺发育不良早产儿中的应用价值

The application value of lung ultrasound findings in preterm infants with bronchopulmonary dysplasia.

作者信息

Gao Shuqiang, Xiao Tiantian, Ju Rong, Ma Rongchuan, Zhang Xiaolong, Dong Wenbin

机构信息

Department of Newborn Medicine, The Affiliated Hospital of Southwest Medical University, Luzhou 646000, China.

Department of Neonatology, Chengdu Women's and Children's Central Hospital, School of Medicine, University of Electronic Science and Technology of China, Chengdu 611731, China.

出版信息

Transl Pediatr. 2020 Apr;9(2):93-100. doi: 10.21037/tp.2020.03.14.

Abstract

BACKGROUND

The purpose of this study was to investigate the association between ultrasound findings and preterm infants with bronchopulmonary dysplasia (BPD).

METHODS

Preterm infants with a gestation age of less than 28 weeks or birthweight less than 1,500 g admitted to the neonatal intensive care unit (NICU) in the Chengdu Women's & Children's Central Hospital from June 2018 to June 2019 were enrolled in the study and divided into 2 groups: the BPD group and the non-BPD group. All clinical data and lung ultrasound were retrospectively analyzed.

RESULTS

A total of 81 neonates (gestational age =29.71±2.27 weeks; birth weight =1,189.5±184.5 g) were enrolled in our center. The regression analysis showed that gestational age [odds ratio (OR) =0.57; 95% confidence interval (CI): 0.42-0.77, P=0.0002], birthweight (OR =0.99; 95% CI: 0.99-1.00, P<0.0001), mild asphyxia (OR =3.3; 95% CI: 1.24-8.74, P=0.0165), anemia (OR =4.43; 95% CI: 1.34-14.64, P=0.0146), blood transfusion (OR =3.68; 95% CI: 1.38-9.79, P=0.0090), respiratory failure (OR =6.58; 95% CI: 1.27-34.08, P=0.0486), heart failure (OR =6.58; 95% CI: 1.27-34.08, P=0.0248), and "debris" lung ultrasound findings (OR =21.82; 95% CI: 2.63-181.11, P=0.0043) were correlated with BPD.

CONCLUSIONS

BPD-related lung ultrasound findings can be a kind of imaging marker to diagnose BPD.

摘要

背景

本研究旨在探讨超声检查结果与支气管肺发育不良(BPD)早产儿之间的关联。

方法

选取2018年6月至2019年6月入住成都市妇女儿童中心医院新生儿重症监护病房(NICU)、孕周小于28周或出生体重小于1500g的早产儿作为研究对象,分为BPD组和非BPD组。对所有临床资料及肺部超声进行回顾性分析。

结果

本中心共纳入81例新生儿(孕周=29.71±2.27周;出生体重=1189.5±184.5g)。回归分析显示,孕周[比值比(OR)=0.57;95%置信区间(CI):0.42-0.77,P=0.0002]、出生体重(OR =0.99;95%CI:0.99-1.00,P<0.0001)、轻度窒息(OR =3.3;95%CI:1.24-8.74,P=0.0165)、贫血(OR =4.43;95%CI:1.34-14.64,P=0.0146)、输血(OR =3.68;95%CI:1.38-9.79,P=0.0090)、呼吸衰竭(OR =6.58;95%CI:1.27-34.08,P=0.0486)、心力衰竭(OR =6.58;95%CI:1.27-34.08,P=0.0248)以及肺部超声“碎片”征(OR =21.82;95%CI:2.63-181.11,P=0.0043)与BPD相关。

结论

与BPD相关的肺部超声表现可作为诊断BPD的一种影像学标志物。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0709/7237972/586e024483f1/tp-09-02-93-f1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验