Suppr超能文献

Effect of heat sterilization and chemical method of sterilization on the polyvinyl siloxane impression material. A comparative study.

作者信息

Asopa Swati Joshi, Padiyar U Narendra, Verma Sumit, Suri Prerna, Somayaji Nagaveni S, Radhakrishnan Indu Cherangapadath

机构信息

Reader, Department of Prosthodontics, Crown and Bridge, Rajasthan Dental College and Hospital, Jaipur, Rajasthan, India.

Professor and Dean, Department of Prosthodontics, Crown and Bridge, Mahatma Gandhi Dental College and Hospital, Jaipur, Rajasthan, India.

出版信息

J Family Med Prim Care. 2020 Mar 26;9(3):1348-1353. doi: 10.4103/jfmpc.jfmpc_1122_19. eCollection 2020 Mar.

Abstract

BACKGROUND

Dental impression is a crucial part of the process of constructing a well-fitting prosthesis. In the clinical scenario, impressions can act as a vehicle for the transfer of bacteria and fungi. Therefore, an attempt was made to evaluate the dimensional accuracy of the newly introduced polyvinyl siloxane (PVS) impression material upon autoclaving and comparing it to the traditional means of chemical disinfection.

MATERIALS AND METHODS

A cross-sectional comparative study was conducted. Three groups were made for testing different sterilization methods. The sample size for the study was kept as 30 observations in each of the three groups. Test samples were prepared by making an impression of the die using the putty-wash technique. Statistical analysis was done by applying unpaired -test, paired -test, one-way analysis of variance (ANOVA) and p h Tukey's honestly significant difference (HSD).

RESULTS

Initial mean of samples of group I were compared to A (actual measurement of metal ruled block = 24.960), a dimensional change of 1.6% was found. Similarly, in group II, a change of 1.59% was found and in group III the change was 1.7%. There was mean shrinkage of 24.557 mm in group I, 24.586 mm in group II, and 24.535 mm in group III and these changes were found statistically significant.

CONCLUSION

Dimensional changes in the impression material after disinfection with 2% glutaraldehyde were considered high compared to autoclaving and, hence, it may not be advisable to disinfect this material with 2% glutaraldehyde.

摘要

相似文献

1
Effect of heat sterilization and chemical method of sterilization on the polyvinyl siloxane impression material. A comparative study.
J Family Med Prim Care. 2020 Mar 26;9(3):1348-1353. doi: 10.4103/jfmpc.jfmpc_1122_19. eCollection 2020 Mar.
3
Margin adaptation of indirect composite inlays fabricated on flexible dies.
J Prosthet Dent. 2000 Mar;83(3):306-13. doi: 10.1016/s0022-3913(00)70133-8.
5
Comparative Evaluation of the Effect of Chemical Disinfectants and Ultraviolet Disinfection on Dimensional Stability of the Polyvinyl Siloxane Impressions.
J Int Soc Prev Community Dent. 2019 Mar-Apr;9(2):152-158. doi: 10.4103/jispcd.JISPCD_406_18. Epub 2019 Apr 12.
6
Evaluation of dimensional stability of autoclavable elastomeric impression material.
J Indian Prosthodont Soc. 2011 Mar;11(1):63-6. doi: 10.1007/s13191-011-0061-1. Epub 2011 Apr 19.
7
Effect of wash bulk on the accuracy of polyvinyl siloxane putty-wash impressions.
J Oral Rehabil. 2002 Apr;29(4):357-61. doi: 10.1046/j.1365-2842.2002.00820.x.

本文引用的文献

1
Comparative Evaluation of the Effect of Chemical Disinfectants and Ultraviolet Disinfection on Dimensional Stability of the Polyvinyl Siloxane Impressions.
J Int Soc Prev Community Dent. 2019 Mar-Apr;9(2):152-158. doi: 10.4103/jispcd.JISPCD_406_18. Epub 2019 Apr 12.
3
Comprehensive Review and Comparison of the Disinfection Techniques Currently Available in the Literature.
J Prosthodont. 2019 Feb;28(2):e849-e856. doi: 10.1111/jopr.12597. Epub 2017 Apr 19.
6
Evaluation of dimensional stability and accuracy of autoclavable polyvinyl siloxane impression material.
J Indian Prosthodont Soc. 2013 Dec;13(4):546-50. doi: 10.1007/s13191-012-0168-z. Epub 2012 Aug 7.
7
Evaluation of dimensional stability of autoclavable elastomeric impression material.
J Indian Prosthodont Soc. 2011 Mar;11(1):63-6. doi: 10.1007/s13191-011-0061-1. Epub 2011 Apr 19.
8
In vitro study of transmission of bacteria from contaminated metal models to stone models via impressions.
Clin Oral Investig. 2002 Sep;6(3):166-70. doi: 10.1007/s00784-002-0174-3. Epub 2002 Aug 16.
9
Contamination level of alginate impressions arriving at a dental laboratory.
Clin Oral Investig. 2002 Sep;6(3):161-5. doi: 10.1007/s00784-002-0173-4. Epub 2002 Aug 16.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验