Ginekol Pol. 2020;91(7):373-378. doi: 10.5603/GP.a2020.0067. Epub 2020 Jun 16.
To evaluate magnetic resonance elastography as a tool for characterizing uterine leimyomas.
At total of 12 women with symptomatic leiomyomas diagnosed in physical and ultrasound examinations were enrolled in this pilot study. Before surgery, all patients underwent magnetic resonance elastography of the uterus using a 1.5 T MR whole-body scanner (Optima, GE Healthcare, Milwaukee, WI, USA). Surgical specimens were forwarded for histological examination. The findings were allocated into 3 categories depending on the percentage content of connective tissue: below 15%, from 15 to 30% and more than 30%. The median stiffness of leiomyomas for each of the group was calculated. The U-Mann Whitney test was used for statistical analysis.
The stiffness of the leiomyomas ranged between 3.7-6.9 kPa (median value 4.9 kPa). The concentration of extracellular components in the leiomyomas did not exceed 40%. An increasing trend of the stiffness with the growing percentage of extracellular component was observed. Stiffness of the leiomyomas obtained by MRE varies depending on microscopic composition.
The value of stiffness shows a trend of increasing with the percentage of extracellular component of the leiomyoma. Further studies are required to assess the usefulness of MRE in diagnostics of uterine leiomyomas.
评估磁共振弹性成像作为一种特征化子宫平滑肌瘤的工具。
本研究纳入了 12 名经体格检查和超声检查诊断为有症状的平滑肌瘤的女性。所有患者均在手术前使用 1.5T 全身磁共振扫描仪(Optima,GE Healthcare,Milwaukee,WI,USA)进行子宫磁共振弹性成像。手术标本均进行组织学检查。根据结缔组织的百分比含量将检查结果分为 3 类:低于 15%、15%至 30%和超过 30%。计算每组平滑肌瘤的中位数硬度。采用 U-Mann Whitney 检验进行统计学分析。
平滑肌瘤的硬度范围为 3.7-6.9kPa(中位数为 4.9kPa)。平滑肌瘤中细胞外成分的浓度不超过 40%。随着细胞外成分百分比的增加,硬度呈上升趋势。MRE 获得的平滑肌瘤硬度取决于微观成分。
硬度值随平滑肌瘤细胞外成分的百分比呈上升趋势。需要进一步研究来评估 MRE 在子宫平滑肌瘤诊断中的有用性。